WARNING - THIS APPLIANCE MUST BE EARTHED.
The cooker must be connected by a qualified
electrician to a suitable double - pole control unit
with a minimum rating of 32A and a minimum
contact clearance of 3mm, which should be fitted
adjacent to (but not above) the cooker, in
accordance with IEE regulations.
The power supply cable should conform to BS6004
with a conductor size of 4mm
2
.
The control unit should be easily accessible in the
event of an emergency.
This appliance conforms to EN55014 regarding
suppression of radio and television interference.
The cooker terminals are behind the cover at the rear
The mains cable must pass through the cable clamp
and the screws must be fully tightened. Sufficient
cable should be used to allow the cooker to be
pulled out for servicing. Ensure that the cover is fully
closed and secure afterwards.
Take care not to trap the mains cable when pushing
the cooker into its final position.
Electrical Connection