Indesit KT6G2M Cooktop User Manual


 
CONNECTING TO GAS SUPPLY
Connection to the cooker should be made with an approved appliance flexible
connection to BS 669. A length of 0.9 to 1.25m is recommended. The length of hose
chosen should be such that when the cooker is in situ, the hose does not touch the
floor.
Those cookers converted to use on LPG should be connected with a hose suitable for
LPG and capable of withstanding a pressure of 50 mbar.
An adaptor backplate should be fitted within the shaded area shown, to allow the
cooker to be pushed fully to the wall and to ensure that the flexible hose is only likely
to come into contact with areas at the rear of the cooker that do not exceed a
temperature rise of 70˚C.
23
300
670
STABILITY CHAIN
A hole in the gas inlet valve bracket can be used to engage a stability chain.
Installation Instructions