Indesit P 640 TC (IX) Cooktop User Manual


 
5
the seal without overlapping;
· insert the hob into the hole, making sure it is positioned
centrally and that the edge adheres to the sealant;
· position the hooks "B" correctly, as shown in figure and
then tighten the screws "A" to hold them in place;
Gas supply connection
Check that the appliance is set for the type of gas available
and then connect it to the mains gas piping or the gas
cylinder in compliance with current regulations and
standards.
This appliance is designed and set to work with the gas
indicated on the label situated on the actual hob. If the gas
supply is other than the type for which the appliance has
been set, proceed with replacing the corresponding nozzles
(provided), following instructions given in the paragraph
“Adaptation to different types of gas”.
For trouble-free operation, suitable use of energy and longer
life of the appliance, make sure that the supply pressure
complies with the values indicated in the table 1 "burners
and nozzles specifications, otherwise install a special
pressure regulator on the supply pipe in compliance with
current standards and regulations.
Connect in such a way that the appliance is subjected to
no strain whatsoever.
Either a rigid metal pipe with fittings in compliance with the
standards in force must be used for connecting to the nipple
union (threaded ½"G male fitting) situated at the rear of the
fig.6
200 cm²
fig.8
Instructions for the installer
fig.7
A
B
appliance to the right (fig.8), or flexible steel pipe in compliance
with the standards in force, which must not exceed 2000 mm
in length. Should it be necessary to turn the fitting, the gasket
(supplied with the appliance) must be replaced.
Upon completion of installation, check the gas circuit, the
internal connections and the taps for leaks using a soapy
solution (never a flame). Also check that the connecting pipe
cannot come into contact with moving parts which could
damage or crush it. Make sure that the natural gas pipe is
adequate for a sufficient supply to the appliance when all the
burners are lit.
Important: A pressure regulator, in compliance with the
standards in force, must be inserted when connecting to a
liquid gas supply (in a cylinder).
Adaptation to different types of gas
If the hob is to be converted for use with a type of gas other
than that for which it was set in the factory (indicated on the
label to be found on the hob), the burner nozzles should be
replaced as follows:
Remove the pan supports and the burners.
Unscrew the nozzles “A” (fig.9) using a 7 mm socket
wrench and replace them with the ones which have a
diameter suitable for the type of gas to be used, according
to the table 1 "burners and nozzles specifications".
Reassemble the parts following the instructions in reverse
order.
• On completing the operation, replace the old rating label
with the one showing the new type of gas;
A
Regulation of Air Supply to the Burner
The burners do not need any primary air regulator.
Minimum Regulation
· Put the tap to the low flame position;
· Remove the tap knob and turn the adjusting screw, situated
inside the tap stem (fig.10), using a screwdriver (loosening
the screw increases the height of the flame, tightening
decreases it).
note: the adjusting screw must be fully screwed down for
liquid gas.
· Having obtained the low flame setting required and with
the burner lit, abruptly change the position of the knob
several times from minimum to maximum and vice versa
and check that the flame does not go out.
· In the event of a malfunction on appliances with the security
device (thermocouple) when the gas supply is set at
minimum, increase the minimum supply levels using the
regulator screw.
fig.10
fig.9