Jackson AJ-100CE Dishwasher User Manual


 
SHUTDOWN AND CLEANING (STEAM-HEATED MODELS): At the end of the workday, place the power switch in the OFF
position, secure the flow of steam to the machine and open the door(s). Open the drain valves and allow the machine to drain
completely. Remove the pawl bar assembly (clean as required). Remove the pan strainers and, if equipped, the prewash strain-
ers, run off sheets and scrap basket strainer. Remove the wash and, if equipped, the prewash arms and verify that the nozzles
and arms are free from obstructions. Flush the arms with fresh water. Remove the pump suction strainers and clean out as
required. Remove the rinse tray assembly and clean. Remove the curtains and scrub with a mild detergent and warm water.
Wipe out the inside of the unit and then reassemble with the components previously removed.
SHUTDOWN AND CLEANING (GAS-HEATED MODELS): At the end of the work day, shut down the gas booster in accor-
dance with manufacturer’s instructions. Place the power switch in the OFF position, secure the flow to the machine and open
the door(s). Open the drain valves and allow the machine to drain completely. Remove the pawl bar assembly (clean as
required). Remove the pan strainers and, if equipped, the prewash strainers, run off sheets and scrap basket strainer. Remove
the wash and, if equipped, the prewash arms and verify that the nozzles and arms are free from obstructions. Flush the arms
with fresh water. Remove the pump suction strainers and clean out as required. Remove the rinse tray assembly and clean.
Remove the curtains and scrub with a mild detergent and warm water. Wipe out the inside of the unit and then reassemble with
the components previously removed.
AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: N/A
SECTION 2: INSTALLATION/OPERATION INSTRUCTIONS
DISHMACHINE OPERATION INSTRUCTIONS (CONTINUED)
41