Jackson AJ-100CGP Dishwasher User Manual


 
Right Side
34 [864mm]
21 [533mm]
25 [635mm]
12 [307mm]
25 [635mm]
Table to Table
Overall
Dish Clearance
B
Right to Left
Drive
Unit
Left Side
1
2
[15mm]
84 [2134mm]
With Doors Open
Rear of
Machine
Legend
A - Machine water inlet 3/4" NPT,
180°F Hi-temp,
140°F Low-temp minimum
B - Electrical connection
C - Drain connection 1-1/2" NPT
D - Vent collar - Optional
E - Vent cowl standard
F - Prewash water inlet 3/4" NPT
110°F-140°F
G - Cold water thermostat plumbing
connection 3/4" NPT - Optional
Note: All vertical dimensions are
+/- 1/2" from floor due to
adjustable bullet feet.
4" (102 mm) wide x 16" (406 mm)
long cutout in Vent Cowl/Splash
Shield. Shipped with Cover Plate.
Floor Sink Or Drain
With 3" (76 mm)
Minimum Drain Line
86 [2182mm]
94 [2385mm]
102 [2588mm]
65
1
2
[1665mm]
8
1
2
[218mm]
C
B
64 [1626mm] 22 [557mm]
Base Unit
Prewash
Prewash Plan View Section
with Cold Water Thermostat
16
3
4
[425mm]
16
1
4
[415mm]
F
G
3/4" [19 mm]
Table Turndown
Flange 3/4" Max
21" [533 mm]
Rack Rail Height
Above Dishtable
1/4" [6mm] - 5/16" [8mm]
Rack Rail
Tub
Table
Use Silicone Sealer
Between Table and
Lip of Machine to
Prevent Leakage
Recommended Table Fabrication
Note: Tub Will Accept
a Table Flange
Up to 24 7/8"
[632 mm]
25 [635mm]
4 1/2 [114mm]
8
1
4
[210mm]
21 [533mm]
Drive
Unit
60
1
4
[1530mm]
62
1
2
[1590mm]
29 [737mm]
6 [152mm]
10 [254mm]
4 [102mm]
7 [178mm]
D
E
8 [203mm]
F
24 [610mm]
G
23
1
2
[599mm]
10
1
4
[261mm]
47 [1194mm]
A
53
3
4
[1365mm]
B
C
43 [1092mm]
75
1
2
[1919mm]
66
1
2
[1692mm]
3 [79mm]
A
G
F
1 [25mm]
Front Side
SECTION 1: SPECIFICATION INFORMATION
AJ-86 ELECTRIC - RIGHT TO LEFT
12
AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: 09-29-2007