AJ-64 Conveyor Series Technical Manual 7610-003-30-93
Issued: 05-02-2006 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
ELECTRICAL REQUIREMENTS (CONTINUED)/D226 STEAM BOOSTER PARAMETERS
4
AJ-100CE MODELS
TYPICAL
TOTAL ELECTRICAL
VOL
TS PH HZ AMPS CIRCUIT
208 1 60 148 A 200 AMP
230 1 60 136 A 175 AMP
208 3 60 88 A 110 AMP
230 3 60 81 A 110 AMP
460 3 60 41 A 60 AMP
AJ-100CGP
MODELS
TYPICAL
TOTAL ELECTRICAL
VOL
TS PH HZ AMPS CIRCUIT
208 1 60 28 A 35 AMP
230 1 60 28 A 35 AMP
208 3 60 19 A 25 AMP
230 3 60 19 A 25 AMP
460 3 60 10 A 15 AMP
AJ-100CS MODELS
TYPICAL
TOTAL ELECTRICAL
VOL
TS PH HZ AMPS CIRCUIT
208 1 60 28 A 35 AMP
230 1 60 28 A 35 AMP
208 3 60 18 A 25 AMP
230 3 60 18 A 25 AMP
460 3 60 9 A 15 AMP
NOTE: Always refer to the machine data plate for specific
electrical and water requirements. The material provided
on this page is for reference only and may be subject to
change without notice.
D226 STEAM BOOSTER
ELECTRICAL REQUIREMENTS:
VOLTAGE (V) 208-230
FREQUENCY (HZ) 60
PHASE SINGLE
WATER REQUIREMENTS:
INCOMING WATER TEMPERATURE (MINIMUM) 110°F
FLOW PRESSURE (PSI) 20±5
STEAM REQUIREMENTS:
INCOMING STEAM PRESSURE (PSIG) 15-25
HEAT EXCHANGER SPECIFICATIONS:*
TUBESIDE WORKING PRESSURE (PSI) 125
SHELLSIDE WORKING PRESSURE (PSI) 125
TUBESIDE HYDROSTATIC TEST PRESSURE (PSI) 250
SHELLSIDE HYDROSTATIC TEST PRESSURE (PSI)
188
MAXIMUM OPERATING TEMPERATURE 295°F
MAXIMUM SHELLSIDE STEAM PRESSURE (PSI) 125
* - Indicates typical design criteria but is subject to change
without notice. For more information, contact you authorized
Jackson service representative.
WATER OUTLET SAFETY VALVE
SET PRESSURE (PSI): 125
STEAM RELIEF VALVE SET PRESSURE (PSI): 50