Performance/Capacities
Pot washers
Water usage — 6.5 gallons per cycle
12 cycles per hour
Fully automatic cycle - 260 seconds
Incoming water pressure regulator
Internally mounted electric booster
heater
- Capable of minimum 60°F temper-
ature rise for required 180°F
minimum sanitizing rinse temperature
One (1) 9 KW Heating Element in a
9 1/2 gallon rinse tank
Two (2) Rotating Wash Arms -
1 upper & 1 lower
Stationary Rinse Nozzles -
Top & Bottom
40 Gallon Wash Tank
Electromechanical controls
- Safety door switch
- Temperature control thermostat
and low water protection
Construction - 12 & 14 gauge
stainless steel
Operational and cleanability features
- High pressure, all stainless steel
wash arms
- 32” wide x 30” high door opening
- Double filtration system
- Externally mounted spray down
hose with spray gun nozzle
- Waterproof LED ditigal gauges
- Three wash cycles
Installation features
- Stainless steel control panel - easily
accessible
- Adjustable bullet feet
- Detergent/rinse additive signal
connection fuse box
Standard Features
Operating Capacity
Racks per Hour 12
Operating Cycle (Seconds)
Light
Wash Time 180
Dwell Time 20
Rinse Time 60
T
otal Cycle 260
Medium
Wash Time 300
Dwell T
ime 20
Rinse Time 60
Total Cycle 380
Heavy
W
ash Time 420
Dwell T
ime
20
Rinse T
ime
6
0
Total Cycle 500
Operating T
emperatures
W
ash —
°
F (Minimum) 150
Rinse — °F (Minimum) 180
Frame Dimensions (Inches)
Width 36
Depth 51 (53 gas)
Height 84 1/2
Height (door open)
Electric 106
Gas 108 1/2
W
all Clearanse (Minimum) 16
Wall Clearance
(Control Panel Side)
36 Wall
Clearance (Back) 12
Shipping Weight (Lbs.) 1150
Shipping Size (Inc
hes)
W
idth
42
Depth 60
Height
9
0
Electrical Rating
Wash Pump Motor Horsepower 10.0
Full Load Amps 208V 230V 460V
Electric 79.0 72.2 37.1
Steam Injectors 54.0 49.6 25.8
Steam Coils 29.0 27.0 14.5
Gas 54.0 49.6 25.8
Gas Requirements
Gas Connection (N
PT) 1/2
Natural Gas (Inc
hes-water column)
Minimum inlet 7.0
Main Manifold 6.0
BTU 48,000
Propane (Inc
hes-water column)
Minimum inlet 11.0
Main Manifold 11.0
BTU 48,000
3” Stainless steel chimney on back of machine
Steam Requirements
Steam connection (NPT) 3/4
Injectors (Lbs per hour)
23
Coils (Lbs per hour) 43
Water Requirements
Inlet T
emperature (Minimum) 140°F
Gallons per Hour 78
Gallons per Rack 6.5
Waterline Size I
P
S (Minimum) (Inc
hes) 1/2
Drainline Size IPS (Minimum) (Inches) 1 1/2
Flow Pressure (PSI) 15-25
Power/Connections
FL-14