ElectricalConnections
Unit to be properlycircuit protected and wired according to
local electrical code and National Electrical Code.
hookuF C. _It is advisable that the electrical wiring and "'_
accomplished by a competent electrician.
120/240 VAC or 120/208 VAC 60 Hz. See serial plate on
front of unit for power requirements.
1. Cut hole in cabinet to mount oven. Cutout in cabinet The neutral of this unit is grounded to the frame through the
should be level and straight, green or solid grounding wire. (The green and the white
wires are twisted together at the termination of the conduit.)
Note: There are no provisions to level the unit after it is If local conditions do not permit grounding of the neutral,
installed. An oven that is not level could cause untwistthe greenwire and connectthe green wireto ground
poor baking results, in accordance with local codes. Connect the white neutral
to the service neutral.
2. Install plywood floor as shown above.
The chart below recommended the minimum circuit
3. Attach unit to the cabinet with four No. 8xl/2" screws protection and wire size if the appliance is the only unit on
supplied with unit inside of envelope containing these the circuit.
instructions. Pre-drill holes in cabinet for attachment
screws using 1/8" drill. Oven mounting holes are
provided in side trim. RECOMMENDEDMINIMUM
K.W,RATING CIRCUITPROTECTIONWlRESIZE
4. See instructionsbelow for electrical hook-up. ONSER_LPLATE IN_PERS (AWG)
0- 4.8 20 12 _'_
5 =.e User's Manual for operating instructions. 4.9 - 6.9 30 10
7.0- 9.9 40 8
10.0- 11.9 50 8
Installing Bottom Trim Piece 12,0-14.9 60 6
Service
Interruptthesource of electricityto the unitwhen attempting
to repair or service the oven. Failureto do this could result
in a dangerous or even fatal shock.
IMPORTANT- SAVE FOR LOCAL ELECTRICALINSPECTOR'SUSE
PartNo,209630A