Jenn-Air JED3430W Cooktop User Manual


 
Product dimension, cutout and installation specifications are provided for planning purposes only. Before installing
any product, be sure to verify cutout dimensions and electrical/gas connections as actual product dimensions may vary.
JENN-AIR
®
DETAILED PLANNING DIMENSIONS
2 of 4
JRC120017A 07/2012
30" Jx3 ELEcTRIc RADIANT DOwNDRAfT cOOkTOP
JED3430W – 30" x 18
3
8" x 22
1
8"
OPENING/cLEARANcE DIMENSIONS
Side
Cabinet
E*
J
L
N
M
F
D
e
A
B
B
K
v
C
I**
K
H
v
G
C
Side
Cabinet
E*
J
L
N
M
F
D
e
A
B
B
K
v
C
I**
K
H
v
G
C
Side
Cabinet
E*
J
L
N
M
F
D
e
A
B
B
K
v
C
I**
K
H
v
G
C
FRONT VIEW
SIDE VIEW TOp VIEW – CuTOuT
MODEL # JED3430W
in cm
A
Width of combustible area above
cooking surface (min.)
30 76.2
B
Width from cooktop to fixed wall
or other combustible material (min.)
2
1
2 6.4
C
Width to center of vent opening option
8
5
8 21.9
D
Width to outer edge of outlet
10 25.4
E*
Height to bottom of uncovered wood or
metal cabinet above cooking surface (min.)
30 76.2
F
Height to bottom of uncovered wood
or metal cabinet (min.)
18 45.7
G
Height to center of vent opening option
16 40.6
H
Height to top edge of outlet (min.)
12 30.5
I**
Depth to center of vent opening option
16
3
4 42.4
J
Depth of upper cabinet (recommended)
13 33.0
K
Depth from cutout to wall (min.)
1
1
2 3.8
L
Width of cutout
28
7
8 73.4
M
Depth of cutout
21
1
8 53.7
N
Depth from cutout to front of countertop
2 5.1
e
Recommended electrical access location
v
Recommended venting location –
see pages 3-4 for ducting information
* Dimension can be reduced by 6" (15.2 cm) when bottom of wood or metal cabinet
is covered by not less than
1
4" (0.6 cm) flame retardant millboard covered with not
less than No. 28 MSG sheet metal, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
**Based on installation in a 24" (61.0 cm) base cabinet.
ELECTRICAL REQuIREMENTS
240 volt, 60 Hz, AC only, 40-amp fused, electrical circuit is required.
A dedicated circuit is recommended.
VENTING REQuIREMENTS
This cooktop must be exhausted outdoors unless using the duct-free filter
kit (JDA7000WX). Refer to kit instructions for further information.
LOCATION REQuIREMENTS
• To ensure cooktop base clearance, cabinet side walls need to be wider
than the cutout.
• A minimum clearance of 6" (15.2 cm) is recommended between the
side of the cooktop and side wall for maximum ventilation performance.
• A minimum clearance of 2" (5.1 cm) is recommended between the
blower motor and cabinet for proper cooling. A 6" (15.2 cm) clearance
is recommended for servicing access.
• An under counter built-in oven cannot be installed under this cooktop.