3
Notice To Installer
Follow accompanying instructions carefully.
This appliance is designed to always be vented outdoors.
This appliance should be ducted separately from other
vented appliances.
CAUTION
Never use a metal blade to pry knob off. If knob
cannot be easily removed, tuck folds of a
dishtowel under knob skirt and pull upward with
steady, even pressure.
Installation Of Appliance
1. Unpack unit.
2. Provide cutout for countertop and duct opening as
required per page 1.
3. Place unit in the cutout.
4. Loosen cap nuts inside plenum to rotate blower
housing to desired position. Connect outlet blower
housing to vent duct. Tighten cap nuts inside plenum.
5. Remove attachment screw and cover from junction
box. Connect BX cable to knockout on side of the
junction box. Make wire connections, push wires into
junction box. Re-attach cover. Consult local codes for
proper power hookup (figure 1).
6. Test to insure control knobs operate all elements
properly.
FIGURE 1
BX CABLE
JUNCTION BOX
RIGHT CENTER