Jenn-Air JMC2430WS Microwave Oven User Manual


 
4
Electrical Connection
To properly install your microwave oven, you must determine the
type of electrical connection you will be using and follow the
instructions provided for it here.
Microwave oven must be connected to the proper electrical
voltage and frequency as specified on the model/serial
number rating plate. The model/serial number rating plate is
located on the left-hand side trim.
The microwave oven rated 120/240 volt, 20-amp, has 4 wires
(L1, L2, N and G) in the flex conduit and should be connected
to a 20-amp maximum rated circuit, overcurrent protected on
both the L1 and L2 circuits.
A time-delay fuse or circuit breaker is recommended.
Flexible cable from the microwave oven should be connected
directly to the junction box.
Do not cut the conduit. The length of conduit provided is for
serviceability of the microwave oven.
A UL listed or CSA approved conduit connector must be
provided.
If the house has aluminum wiring follow the procedure below:
1. Connect a section of solid copper wire to the pigtail
leads.
2. Connect the aluminum wiring to the added section of
copper wire using special connectors and/or tools
designed and UL listed for joining copper to aluminum.
Follow the electrical connector manufacturer's recommended
procedure. Aluminum/copper connection must conform with
local codes and industry accepted wiring practices.
INSTALLATION INSTRUCTIONS
Prepare Built-In Microwave Oven
1. Locate existing wiring to avoid drilling into or severing wiring
during installation.
2. To avoid floor damage, set the microwave oven onto
cardboard prior to installation. Do not use handle or any
portion of the front frame for lifting.
3. Remove the shipping materials and tape from the microwave
oven.
4. Remove and set aside racks and other items from inside the
microwave oven.
5. Remove the hardware package from inside the bag
containing literature.
6. Move the microwave oven and cardboard close to the
microwave oven’s final location.
Make Electrical Connection
This microwave oven is manufactured with a neutral (white)
power supply wire and a cabinet-connected green (or bare)
ground wire.
1. Disconnect power.
2. Feed the flexible cable conduit from the microwave oven
through the opening in the cabinet.
A.Model/serial number plate
A
WARNING
Excessive Weight Hazard
Use two or more people to move and install
microwave oven.
Failure to do so can result in back or other injury.
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Use 12 gauge solid copper wire.
Electrically ground oven.
Failure to follow these instructions can result in death,
fire, or electrical shock.