Jenn-Air W10526080A Cooktop User Manual


 
11
Typical flexible connection.
4. Install the pressure regulator with the arrow pointing up
toward the bottom of the cooktop base and in a position
where you can reach the regulator access cap.
IMPORTANT: All connections must be wrench-tightened. Do
not make connections to the gas regulator too tight. Making
the connections too tight may crack the regulator and cause
a gas leak. Do not allow the regulator to turn on the pipe
when tightening fittings.
Use only pipe-joint compound made for use with Natural and LP
gas.
Do not use TEFLON
®
tape. You will need to determine the fittings
required depending on your installation.
Complete Connection
1. Open the manual shutoff valve in the gas supply line. The
valve is open when the handle is parallel to the gas pipe.
2. Test all connections by brushing on an approved
noncorrosive leak-detection solution. If bubbles appear, a
leak is indicated. Correct any leak found.
3. Remove surface burner caps and grates from parts package.
Align notches in burner caps with pins in burner base. Burner
caps should be level when properly positioned. If burner caps
are not properly positioned, surface burners will not light.
Place burner grates over burners and caps.
4. Plug into a grounded 3 prong outlet.
A.Manifold entrance
B.Gas pressure regulator
C.Use pipe-joint compound.
D.Adapter (must have ½" male pipe thread)
E.Flexible connector
F. Ada pt er
G.Use pipe-joint compound.
H.Manual gas shutoff valve
I.½" or ¾" gas pipe
A.Access cap
B.Rear of cooktop
C.Gas pressure regulator
D.Up arrow. Regulator must be installed with
arrow pointing up to cooktop bottom.
A
B
D
E
C
F
G
H
I
A
B
C
D
A. Closed valve
B.Open valve
A.Burner cap
B.Burner ports
C.Burner base
D.Gas tube opening
E.Igniter head
A
B
A
B
C
D
E
Electrical Shock Hazard
Plug into a grounded 3 prong outlet.
Do not remove ground prong.
Do not use an adapter.
Do not use an extension cord.
Failure to follow these instructions can result in death,
fire, or electrical shock.
WARNING