Jenn-Air W2451 Oven User Manual


 
SECTION 3. TROUBLESHOOTING
Test Access The test mode can be accessed by holding the stop time key down at
power up or by holding the stop time key down for 10 seconds within 5
minutes of power up mode, No other key can be pressed before the
stop time key, that would block the test mode access.
Test Exit Exit the test mode by pushing the cancel key or test will self-terminate
after 16 seconds from the last key command chosen.
Test Function Test mode is perfomed by pushing a keypad and testing for an output
response. When the keypad is released, the output is terminated and
the display will return to the "-" display. The following is a list of key
actions and responses.
NOTE:
1. Each time a key is pressed a tone will sound.
2. If there is a red dot on the IC-chip and the display board when you touch the oven light key,
the oven light will come on and a beep will occur. The beep is to let you know that there is
a good circuit, in case the light is blown. Also, when you press the fan speed key on a dual
speed downdraft, it will beep each time you touch the key. The first beep will be the high
setting, the second beep will be the low setting, and the third beep will be off.
Bake Key
Broil Key
Convect Bake Key
Convect Roast Key
Oven Light Key
Probe Key
Timer Keys
Clean Key
Activates bake relay on the power relay board.
Activates broil relay on the power relay board.
Activates convect bake relay (CVBAK) on the power relay board.
Activates convect roast relay (CVRST) on the power relay board.
Activates oven light (OVLT) relay on the power relay board. (See note
2 above.)
Activates the display on the control to display the probe temperature.
Activates the display to show factory codes in the blue displayed digits
and oven temperature in red.
Activates blue display digits which shows the state of the door lock
switches and the status of the user selectable options. See charts on
page 1-2. NOTE: First (left) blue displayed digit is for user selectable
options code and the fourth (right) blue digit is for the door lock switch
status code.
16009721 TROUBLESHOOTING 3-1
O1999 Maytag Appliances Sales Company