John Lewis JLFFW2005 Freezer User Manual


 
11
Any electrical work required to install this appliance should
be carried out by a qualified electrician or competent
person.
WARNING: THIS APPLIANCE MUST BE
EARTHED.
Should the appliance power supply cable need
to be replaced, this must be carried out by a
Service Force agent (see page 22)
The manufacturer declines any liability should
this safety measure not be observed.
Before switching on, make sure the electricity supply voltage
is the same as that indicated on the appliance’s rating plate.
(See picture on page 5).
The appliance is supplied with a 13amp plug supplied. In the
event of having to change the fuse in the plug supplied, a
13amp ASTA approved BS 1363/A fuse must be used.
Should the plug need to be replaced for any reason, proceed
as described below.The wires in the mains lead are coloured
in accordance with the following code:
Green and Yellow - Earth
Blue - Neutral
Brown - Live
If you fit your own plug, the colours of the wires in the
mains lead of your appliance may not correspond with the
markings identifying the terminals in your plug.
Proceed as follows:
1. Connect the Green and Yellow (earth) wire to the
terminal in the plug which is marked with the letter "E"
orthe earth symbol or coloured green and yellow.
2. Connect the Blue (neutral) wire to the terminal in the
plug which is marked with the letter "N" or coloured black.
3. Connect the Brown (live) wire to the terminal in the
plug which is marked with the letter "L" or coloured red.
4. Upon completion there must be no cut, or stray strands
of wire present and the cord clamp must be secure over the
outer sheath.
WARNING:
A cut off plug inserted into a 13 amp socket
is a serious safety (shock) hazard.
Ensure that the cut off plug is disposed of
safely.
The plug must still be accessible after the
appliance has been installed.
The appliance should not be connected to
the electrical supply by means of an
extension cable
Permanent connection
In the case of permanent connection it is necessary that
you install a double pole switch between the appliance
and the electricity supply (mains), with a minimum gap of
3mm between the switch contacts and of a type suitable
for the required load in compliance with the current
electrical regulations.
The switch must not break the green and yellow earth
cable at any point.
Electrical connection