www.keatingofchicago.com 1-800-KEATING
SERVICE INSTRUCTIONS
REMOVAL OF ELEMENTS ON ELECTRIC FRYERS
The Keating Elements provide maximum output and have stainless steel surfaces to make
cleaning easier and provide maximum heat transfer to the oil and food products.
Removal:
1. Disconnect electric power source.
2. Drain oil into approved container and set aside.
3. Loosen two thermostat bulb clamps on upper element and slide clamps away from
thermostat bulb. For 18” and 20” fryers, remove two element spacers by loosening two
screws on each spacer. Carefully note position of spacers onto elements.
4. Remove control panel.
5. Remove contractor shield by removing two screws.
6. Remove black and red wires from both ends of faulty element by unscrewing terminal
binding post screws.
7. Remove element by unscrewing nuts and removing washers from both ends of element.
NOTE FOR REPLACING ELEMENTS ON ELECTRIC FRYERS
WHEN REPLACING OLD ELEMENTS ON OLD FRYERS IN THE FIELD, ALL WIRES LEADING
TO THE ELEMENTS FROM THE CONTACTORS SHOULD HAVE BUTT CONNECTORS
ATTACHED TO THE ENDS OF THE WIRES. tHE BUTT CONNECTORS SHOULD BE CRIMPED
ONTO THE EXPOSED WIRES. THE BUTT CONNECTORS ARE THEN PUT THROUGH THE
HOLES ON ELEMENTS AND TIGHTENED DOWN WITH THE SCREW. MAKE SURE THE BUTT
CONNECTOR IS PUSHED HALFWAY THROUGH THE HOLE ON THE ELEMENT SO THAT THE
SCREW TIGHTENS ON THE BUTT CONNECTOR CLOSEST TO THE WIRE INSULATION.
elcfryer.qxp