THERMOSTAT CALIBRATION
Calibration is not covered under warranty.
Tools: Accurate surface thermometer
Standard screwdriver
1. Turn the exhaust system ON.
2. Turn on the griddle with thermostat set at 300°F. Allow
burners to cycle on and off three times. (Approximately
60 minutes.)
3. Place accurate thermometer on surface over thermostat
bulb. Use the inverted “V” on the front of the griddle plate
to locate thermostat bulb. Place the surface
thermometer about half waytoward the back of the plate.
4. When burners cycle off, the griddle is up to temperature.
If temperature is within 25°F of thermostat setting,
remove knob. Loosen four screws in the thermostat dial
plate. Replace knob. Reset the dial plate to match the
thermometer reading.
Thermostat calibration
Thermostat knob removed to reveal calibration screws.
5. Remove the knob to tighten screws on dial plate and
replace the knob.
For calibration over a 50°F difference, contact a qualified
service company.
DO NOT ADJUST THE THERMOSTAT SET
SCREW - IT VOIDS ANY WARRANTY ON
CONDITIONING THE
MIRACLEAN
®
GRIDDLE PLATE
The Miraclean
®
Griddle plate has been “seasoned” at the
factory. The Miraclean
®
surface when heated creates a thin
layer of chrome oxide which acts as a releasing agent for
food product. You may feel that you need to recondition
your griddle surface.
1. Follow cleaning instructions on page 5.
2. Heat the MIRACLEAN
®
to 400°F for one hour.
3. Lower thermostat to 350°F, allowing the MIRACLEAN
®
to
cool to about 350°F, as is evident when griddle cycles on
or surface thermometer indicates correct temperature.
4. Lightly coat the MIRACLEAN
®
surface with griddle oil.
NOTE: Despite the food releasing properties, the chrome surface is not a true
“non-stick” surface. For best cooking results and product appearance, use
griddle oil for products that require the surface to be conditioned.
PARTS ORDERING
Parts may be ordered by part number by calling Keating at 1-
800-KEATING or your service company. You may also order
on-line at Keating’s part store, www.keatingofchicago.com.
Refer to the Keating MIRACLEAN
®
Griddle Limited Warranty
for complete service and ordering information.
The model/serial plate is located inside the cabinet. Remove
grease drawer. The model and serial numbers are necessary
when ordering.
7
TIME OPERATOR/OWNER
FRAME
At Least Clean MIRACLEAN
®
Griddle surface.
Daily
Drain and clean grease drawer.
Completely wipe down MIRACLEAN
®
Griddle cabinet.
At Least
Check MIRACLEAN
®
Griddle surface
Monthly* to insure proper maintenance.
(Review proper cooking procedures.)
Check calibration of thermostats.
Review operating instructions
received with MIRACLEAN
®
griddle.
Every
Clean gas valve vent tube.
6 Months* Check burner manifold pressure.
At Least QUALIFIED SERVICE PERSONNEL ONLY
Yearly* Have MIRACLEAN
®
griddle completely
checked, calibrated, tested, cleaned, etc.
by qualified service personnel. Be sure to
check color and height of pilot flame.
*High production facilities should be checked more often. Contact the
factory or a local service company to perform maintenance and repairs.
PROBLEM SOLUTION
Miraclean
®
Griddle • Is the gas connected?
does not operate: • Is the gas supply turned on?
• Is the gas valve knob in the ON
position?
• Is the pilot lit?
• Is the switch turned on?
• Is the thermostat set at the desired
position?
PART