PRODUCT DATA SHEETS
Base Grille Water Filtration System
Model WF-NLC240V/NLC240V Capacity 240 Gallons (908 Liters)
I Tested and certified by NSF International against ANSI/NSF Standard
42 for the reduction of Chlorine, Taste and Odor, Particulate Class I*;
and against ANSI/NSP Standard 53 for the reduction of Lead,
Mercury, Atrazine, Benzene, Toxaphene, p-dichlorobenzene, 2, 4-D,
Cysts, Turb d ty and Asbestos.
This system has been tested according to ANSI/NSF 42/53 for the reduction of the substances listed below. The concentration of
the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for
water leaving the system, as specified in ANSI/NSF 42/53.
Substance Reduction NSF Reduction Average Influent Challenge Maximum Average Minimum % Average% NSF Test
Aesthetic Effects Requirements Influent Concentration Effluent Effluent Reduction Reduction Number
Chlorine Taste/Odor 250% 2.0 mg/L 2.0 mg/L ± 10% 0.06 mg/L 0.05 mg/L 97.t % 97.5% 507173-02
particles/ml 4,10O/mL** 2,30O/mL 99.3% 99.9%
Particulate Class I* 285% _366,667/ At least 10,000 507175-02
Contaminant NSF Reduction Average Influent Challenge Maximum Average Minimum % Average% NSF Test
Reduction Requirements Influent Concentration Effluent Effluent Reduction Reduction Number
Lead: @pH 6.5 0.01mg/L 0.16 mg/L*** 0.15 mg/L ± 10% 0.001 mg/L 0.001 mg/L 99.35% 99.35% 507601-01
Lead: @pH 8.5 0.Olmg/L 0.15 mg/L*** 0.15 mg/L ± 10% 0.001 mg/L 0.001 mg/L 99.31% 99.3t% 507602-01
Mercury: @ pH 6.5 0.002 mg/L 0.0061 mg/L 0.006 mg/L ± 10% 0.0004 mg/L 0.0002 mg/L 93.5% 96.7% 507603-02
Mercury: @ pH 8.5 0.002 mg/L 0.0057 mg/L 0.006 mg/L ± 10% 0.0008 mg/L 0.00051 mg/L 85.8% 91.2% 507604-02
Benzene 0.005 mg/L 0.0138 mg/L 0.015 ± 10% 0.0005 mg/L 0.0005 mg/L 96.3% 96.3% 507183-02
p-dichlorobenzene 0.075 mg/L 0.220 mg/L 0.225 ± 10% 0.0005 mg/L 0.0005 mg/L 99.7% 99.7% 507186-02
Toxaphene 0.003 mg/L 0.014 mg/L 0.015 ± 10% 0.0014 mg/L 0.001 mg/L 90.0% 92.9% 507185-02
Atrazine 0.003 mg/L 0.009 mg/L 0.009 mg/L ± 10% 0.0013 mg/L 0.00036 mg/L 85.6% 95.9% 507181-02
2, 4-D 0.07 mg/L 0.197 mg/L 0.215 ± 10% 0.058 mg/L 0.0137 mg/L 70.6% 93.06% 507180-02
Asbestos 99% 26 x 107 107to lO_fibers/L ***' 0.18 x 107mg/L 0.18 x 107 mg/L 99.93% 99.93% 507178-02
Cysts ..... 99.95% 111,000/mL 50,0O0/L min. 1 mg/L 1 mg/L 99.99% 99.99% 507187-02
Turbidity 0.5 NTU 11.08 NTU 1 t ± 1 NTU 0.13 NTU 0078 NTU 98.8% 99.3% 507751-02
Test Parameters: pH = 7.5 _+0.5 unless otherwise noted. Flow = 0.5 gpm (1.9 Lpm). Pressure = 60 psig (413.7 kPa). Temp. = 63°F
(17.2°C).
• It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
• Model WF-NLC240V Change cartridge at least every 6-9
months. Use replacement cartridge NLC240V, part #9908.
2003 suggested retail price of $39.95 U.S.A./S49.95 Canada.
Prices are subject to change without notice.
• The product is for cold water use only.
• Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• Refer to the front cover or "Accessories" section for the
Manufacturer's name, address and telephone number.
• Refer to the "Warranty" section for the Manufacturer's limited
warranty.
Application Guidelines/Water Supply Parameters
Water Supply City or Well
Water Pressure 30 - 129 psi (297 - 827 kPa)
Water Temperature 33 ° - 109°F (0.6 ° - 37.8 ° C)
Service Flow Rate 9.5 gpm (1.9 L/min.) @ 60 psi.
*Class I particle size: >0.5 to <1 um
*_Test requirement is at least 100,000 particles/mL of AC Fine Test Dust.
***These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
****Fibers greater than 10 um in length
*****Based on the use of Cryptosporidium parvum oocysts
® NSF is a registered trademark of NSF International.
24