Kenmore 721.80044 Microwave Oven User Manual


 
STEP 3:
PREPARE THE VENTING BLOWER
ROOF VENTED INSTALLATION:
1. Remove one blower unit mounting screw and
two blower plate screws. Remove the blower
plate from cabinet. See Figure 18.
blower plate
mounting
screws
2. Carefully lift the blower unit out of the
microwave oven.
3. Rotate blower unit 90° so the exhaust ports
face the top of the cabinet. See Figure 19.
blower plate
blower unit
mounting screw
Figure 18
4. Place blower unit back into microwave oven.
5. Use side cutters or tin snips to cut and remove
knockouts "A" from blower plate. Discard
knockouts. Be careful not to distort the plate.
See Figure 20.
6. Reattach blower plate to microwave oven.
Attach with the one blower unit mounting
screw and then the two blower plate mounting
screws. See Figure 21.
Figure 19
blower
unit
Knockouts "A"
/
blower plate
Figure 20
blower unit
blower plate
mounting
screws
blower plate blower unit
mounting screws
Figure 21