Kenmore 721.80403 Microwave Oven User Manual


 
STEP 3:
PREPARE THE VENTING BLOWER
ROOF VENTED INSTALLATION:
1. Remove two blower unit mounting screws and
one or two blower plate mounting screws. Remove the
blower plate from cabinet. See Figure 18.
blower plate
mounting
screws
2. Carefully lift the blower unit out of the
microwave oven.
3. Rotate blower unit 90° so the exhaust ports
face the top of the cabinet. See Figure 19.
4. Place blower unit back into microwave oven.
5. Use side cutters or tin snips to cut and remove
knockouts "A" from blower plate. Discard
knockouts. Be careful not to distort the plate.
See Figure 20.
6. Reattach blower plate to microwave oven.
Attach with the one blower unit mounting
screw and one or two blower plate mounting
screws. See Figure 21.
blower plate
bl,
mounting screws
Figure 18
blower
unit
Figure 19
Knockouts "A"
/
blower plate
Figure 20
blower unit
blower plate
mounting
screw
blower plate blower unit
mounting screw
Figure 21
12