PROBLEM
TOP BURNERS DO NOT
LIGHT OR DO NOT
BURN EVENLY
Q
BURNER FLAMES VERY
LARGE OR YELLOW
SURFACE BURNERS
LIGHT BUT OVEN
DOES NOT
POSSIBLE CAUSE
Make sure electrical plug is plugged into a live power outlet.
Burner holes on the side or around the top of burner may be clogged,
Remove burners (on models with standard twin burners) or burner heads
(on models with sealed burners] or burner caps on spill-proof models, and
clean them with a sewing needfe or twist-tie. Make sure you do not enlarge
the holes., On spiIFproof models, check electrode area for burned-on food
or grease.
Make sure the drip pans (on some models) are installed correctly.
Pilot(s) is (are) no; lit (on standing pilot models). See the Lighting
Instructions for Standing Pilot Models section in Surface Cooking
If range is connected to LP gas, contact the person who installed your range
or made the conversion.
The oven gas shut-off valve may have accidentally been moved during
cleaning or moving
To check the oven gas shut-off valve on standard twin burner models, raise the
cooktop and look for the gas shut-off lever at the extreme right rear corner,
Follow the directions in box A or B that match your regulator type.
Lever shown closed/
Standard Twin Burner Models
Lever shown closed/
Standard Twin Burner Models
To check the oven gas shut-off valve on sealed burner models, remove
the broiler drawer and bok for the gas shut-off lever at the back of the range,
i
I Lever shown )
Sealed Burner Models
4O