Kenmore 362.72232 Range User Manual


 
1. Installa manualgaslineshut-offvalveinthegasline
inaneasily accessed location outside of the range.
Make sure everyone operating the range knows where
and how to shut off the gas supply to the range.
2, Install male V2"flare union adapter to the 1/2"NPT
internal thread at inlet of pressure regulator.
Use a back-up wrench on the regulator fitting
to avoid damage_
3. Install male V2"or 3/4"flare union adapter to the NPT
internal thread of the manual shut-off valve, taking care
to back up the shut-off valve to keep it from turning.
4, Connect flexible metal appliance connector to the
adapter on the range. Position range to permit
connection at the shut-off valve.
5, When all connections have been made, make sure
all range controls are in the OFF position and turn on
the main gas supply valve. Use a liquid ieak detector
at all joints and connections to check for leaks in
the system°
WARNING: Do NOT USE A FLAME TO
CHECK FOR GAS LEAKS.
When using test pressures greater than V2psig to
pressure test the gas supply system of the residence,
disconnect the range and individual shut-off valve from
the gas supply piping. When using test pressures of
V2psig or less to test the gas supply system, simply
isolate the range from the gas supply system by closing
the individual shut-off valve..
34
STEP 3
Electrical Connections
(on some models)
Electrical Requirements
120-volt, 60 Hertz, properly grounded branch circuit
protected by a 15-amp or 20-amp circuit breaker or time
delay fuse°
Extension Cord Cautions
Because of potential safety hazards associated with
certain conditions, we strongly recommend against the
use of an extension cord_ However, if you still elect to use
an extension cord, it is absolutely necessary that it be a
UL-listed, 3-wire grounding-type appliance extension cord
and that the current carrying rating of the cord in amperes
be equivalent to, or greater than, the branch circuit rating..
Grounding--IMPORTANT (Please read carefully)
FOR PERSONAL SAFETY_ THIS APPLIANCE MUST
BE PROPERLY GROUNDED.
The power cord of this
appliance is equipped
with a three-prong
(grounding) plug which
mates with a standard
three-prong grounding
wall receptacle to
minimize the possibility of
electric shock hazard
from this appliance.
The customer should
have the wall receptacle
PREFERRED
METHOD
Ill Ensure proper
ground exists
I tFI before use
and circuit checked by a qualified electrician to make
sure the receptacle is properly grounded.
Where a standard two-prong wall receptacle is
encountered, it is the personal responsibility and
obligation of the customer to have it replaced with
a properly grounded three-prong wall receptacle.
DO NOT_ UNDER ANY CIRCUMSTANCES, CUT OR
REMOVE THE THIRD (GROUND) PRONG FROM THE
POWER CORD.
A word about GFCI's - GFCI's are not required or
recommended for gas range receptacles.
Ground Fault Circuit Interrupters (GFCI's) are devices that
sense leakage of current in a circuit and automatically
switch off power when a threshold leakage level is
detected.. These devices must be manually reset by the
consumer.. The National Electrical Code requires the use of
GFCI's in kitchen receptacles installed to serve countertop
surfaces. Performance of the range wil! not be affected if
operated on a GFCl-protected circuit but occasional
nuisance tripping of the GFCI breaker is possible.