Kenwood CK 300 Range User Manual


 
36
TABLE FOR THE CHOICE OF THE INJECTORS
Cat: II 2H3+
INCREASE OF AIR NECESSARY FOR GAS COMBUSTION
(2 m
3
/h x kW)
BURNERS Air necessary for combustion [m
3
/h]
Auxiliary (A) 2,00
Semi-rapid (SR) 3,50
Rapid (R) 6,00
Triple-ring 7,00
Left Oven
7,40
Left Grill
5,00
Right Oven
4,40
Right Grill
4,00
BURNERS
Auxiliary (A) 1,00 0,30 27 50 -
adjustable
72 (X) -
Semi-rapid (SR) 1,75 0,45 32 65 -
adjustable
97 (Z) -
Rapid (R) 3,00 0,75 42 85 -
adjustable
115 (Y) -
Triple-ring (TR) 3,50 1,50 65 95 -
adjustable
135 (T) -
Left Oven
3,70 0,75 42 92
fully open* adjustable
140 5 *
Left Grill
2,50 - - 80
fully open*
- 120 4 *
Right Oven
2,20 0,63 39 72
fully open* adjustable
110 4 *
Right Grill
2,00 - - 70
fully open*
- 105 2 *
Nominal
Power
[kW]
Reduced
Power
[kW]
G 30 - 28-30 mbar
G31- 37 mbar
G 20
20 mbar
By-pass
[1/100 mm]
By-pass
[1/100 mm]
Ø injector
[1/100 mm]
Ø injector
[1/100 mm]
GB
*
= Reference value
Ring opening
[mm]
Ring opening
[mm]