Kenyon UL/C-UL Cooktop User Manual


 
For future reference, please record the serial number of your
cook top here:
STEP #2
Check the Electrical Supply Requirements
This product must be installed in accordance with national, state and local electric codes.
The following table provides the correct voltage, amperage and frequency that must be
supplied to the cook top.
The supply must be from an individual grounded circuit that is protected by a circuit breaker
and rated per the specifications for the various models as shown in the table above.
2
Max Connected Required Power Minimum
Kenyon Part # Model # Load Supply Input Wire Size
B41511 MED2 3000 Watts 240 VAC/12.5A/60Hz #12 AWG
B41516 MED2TL 2400 Watts 240 VAC/10A/60Hz #12 AWG
B41518 MED1 1200 Watts 240 VAC/5A/60Hz #12 AWG
B41602 CAR2 2400 Watts 240 VAC/10A/60Hz #12 AWG
B41606 CAR1 1200 Watts 240 VAC/5A/60Hz #12 AWG
B49511 ALP2LG 3000 Watts 240 VAC/12.5A/60 Hz #12 AWG
B49516 ALP2SM 2400 Watts 240 VAC/10A/60Hz #12 AWG
B49518 ALP1 1200 Watts 240 VAC/5A/60Hz #12 AWG
!
Warning: If the electric power supply does not meet the
product specifications, consult with a licensed electrician
before proceeding with installation.