KitchenAid 4360369 Ventilation Hood User Manual


 
Before you start...
Proper installation is your
responsibility:
• Have a qualified technician install
this range hood.
• Comply with installation clearances
specified on the model/serial rating
plate.
Model/serial rating plate is located
inside the range hood on the rear
wall.
Island canopy hood location should
be away from strong draft areas, such
as windows, doors and strong heating
vents.
Grounded electrical outlet is required.
See “Electrical requirements.”
Note:The island canopy hood is
factory set for venting through the
roof or wall. For non-vented
(recirculating) installations see “Non-
Vented (Recirculating) Kits” on the
back page.
All openings in ceiling and wall where
range hood will be installed must be
sealed.
Important: Observe all governing
codes and ordinances.
Parts supplied:
6 screws
mounting
template
upper
chimney
trim
support
system
8 trim
clips
support
mounting
bracket
upper
chimney
lower
chimney
trim
upper
chimney
trim
lower
chimney
trim
canopy
damper
lower
chimney
Parts needed:
2 U.L.- or C.S.A.- listed, 1/2" (12.5 mm)
conduit connectors
power supply cable
1 wall or roof cap
metal vent system
allen wrench set
Tools needed:
Phillips
screwdriver
flat-blade
screwdriver
caulking gun and
weatherproof
caulking
compound
duct tape
metal
snips
pliers
pencil
saber or
keyhole saw
drill
1-1/4" drill bit
level
measuring
tape or ruler
wire stripper
or utility knife
WARNING — TO REDUCE THE
RISK OF FIRE, ELECTRIC SHOCK,
OR INJURY TO PERSONS,
OBSERVE THE FOLLOWING:
Installation work and electrical
wiring must be done by qualified
person(s) in accordance with all
applicable Codes and Standards,
including Fire Rated
Construction. The combustion
airflow needed for safe
operation of fuel-burning
equipment may be affected by
this unit’s operation. Follow the
heating equipment
manufacturer’s guideline and
safety standards such as those
published by the National Fire
Protection Association (NFPA),
and the American Society of
Heating, Refrigeration and Air
Conditioning Engineers
(ASHRAE), and the local code
authorities.
When cutting or drilling into wall
or ceiling, do not damage
electrical wiring and other
hidden utilities.
Ducted fans must always be
vented to the outdoors.
WARNING — To reduce the risk
of fire, use only metal ductwork.
This unit must be grounded.
2
This is the safety alert symbol.
This symbol alerts you to
potential hazards that can kill
or hurt you and others. All safety
messages will follow the safety alert
symbol and either the word “DANGER”
or “WARNING”. These words mean:
You can be killed or seriously injured
if you don’t follow instructions.
DANGER
WARNING
Your safety and the safety of
others is very important.
We have provided many important
safety messages in this manual and
on your appliance. Always read and
obey all safety messages.
All safety messages will tell you what
the potential hazard is, tell you how to
reduce the chance of injury, and tell
you what can happen if the
instructions are not followed.
You can be killed or seriously injured
if you don’t immediately
follow
instructions.