KitchenAid 9759121A Convection Oven User Manual


 
5
Mobile Home - Additional Installation Requirements
The installation of this range must conform to the Manufactured
Home Construction and Safety Standard, Title 24 CFR, Part 3280
(formerly the Federal Standard for Mobile Home Construction
and Safety, Title 24, HUD Part 280). When such standard is not
applicable, use the Standard for Manufactured Home
Installations, ANSI A225.1/NFPA 501A or with local codes.
In Canada, the installation of this range must conform with the
current standards CAN/CSA-A240-latest edition, or with local
codes.
Mobile home installations require:
When this range is installed in a mobile home, it must be
secured to the floor during transit. Any method of securing
the range is adequate as long as it conforms to the standards
listed above.
Product Dimensions
*When installed in a 24" (61 cm) base cabinet with 25" (63.5 cm)
countertop; front of oven door protrudes 1⁷⁄₈" (4.8 cm) beyond
24" (61 cm) base cabinet.
Installation Clearances
Cabinet opening dimensions shown are for 25" (64 cm)
countertop depth, 24" (61 cm) base cabinet depth and
36" (91.4 cm) countertop height.
*NOTE: 36" (91.4 cm) minimum when bottom of wood or metal
cabinet is protected by not less than ¹⁄₄" (0.64 cm) flame
retardant millboard covered with not less than No. 28 MSG
sheet steel, 0.015" (0.4 mm) stainless steel, 0.024" (0.6 mm)
aluminum or 0.020" (0.5 mm) copper.
42" (106.7 cm) minimum clearance between the top of the
cooking platform and the bottom of an unprotected wood or
metal cabinet.
If installing a hood above the range, follow the hood instructions
for dimensional clearances above the cooktop surface.
A.Backguard (required for some installations)
B.45" (114.3 cm) overall height
C.36" (91.4 cm) cooktop height with feet
loosened ¾ turn
D.30" (76.2 cm) width
E.26½" (67.3 cm) width with control panel*
F. ¼" (6.4 cm) spacer
G.9¼" (23.5 cm) backguard height
A
B
C
D
E*
F
G
A.18" (45.7 cm) upper cabinet to countertop
B.22" (55.9 cm)
C.Junction box to be located in this shaded area
D.4" (10.2 cm)
E.20" (50.8 cm)
F. 12" (30.5 cm)
G.5½" (14 cm)
H.Gas line opening to be located in this shaded area
I.3½" (8.9 cm)
J.8" (20.3 cm)
K.30¼" (76.8 cm)
L.4" (10.2 cm) min. clearance from both sides of range
to side wall or other combustible material
M.For minimum clearance to top of range, see NOTE*.
N.30" (76.2 cm) min. upper cabinet width
O.13" (33 cm) max. upper cabinet depth
B
C
D
E
F
G
H
I
J
L
M
K
N
O
*
A