KitchenAid 9763382 Ventilation Hood User Manual


 
4
Product Dimensions
Location Requirements
IMPORTANT: Observe all governing codes and ordinances.
Island hood location should be away from strong draft areas,
such as windows, doors and strong heating vents.
Cabinet opening dimensions that are shown must be used. Given
dimensions provide minimum clearance.
Grounded electrical outlet is required. See “Electrical
Requirements” section.
It is recommended that the hood be fastened into solid wood.
The island hood is factory set for venting through the roof or wall.
For recirculating installations see “Recirculating Installations” in
“Install Chimney Covers” section.
All openings in ceiling and where island hood will be installed
must be sealed.
Tools and Parts
Gather the required tools and parts before starting installation.
Read and follow the safety instructions provided with any tools
listed here.
Tools needed:
level
drill with 1¹⁄₄" (3.0 cm) drill bit
pilot hole drill bit (determined by chimney support
attachment method)
pencil
wire stripper or utility knife
measuring tape or ruler
pliers
caulking gun and weatherproof caulking compound
duct tape
jig saw or keyhole saw
flat blade screwdriver
metal snips
Phillips screwdriver
Parts needed:
2 UL- or CSA- listed, ¹⁄₂" (12.5 mm) strain reliefs
power supply cable
1 wall or roof cap
metal vent system
4, concrete anchors for ¹⁄₄" x 4" hex head lag bolts if
installing into concrete
Parts supplied:
Remove parts from packages. Check that all parts were included.
hood canopy assembly with ventilator and light bulbs installed
chimney assembly
ceiling template
Installation Instructions and Use & Care Guide
3 filters
hardware package (4 wood shelf bolts, 4 wood shelf bolt
washers, 4 wood shelf nuts, 4 concrete plugs, 1 mounting
template, 1 damper)
INSTALLATION REQUIREMENTS
23
⁵⁄₈
"
(60.0 cm)
13
³⁄₄
"
(34.9 cm)
12
¹⁄₁₆
"
(30.6 cm)
4
³⁄₄
"
(12.1 cm)
35
³⁄₈
" (89.9 cm)
27
¹⁄₂
"
(69.9 cm)
26
³⁄₈
" (65.1 cm)
min.
39" (99.1cm)
max.
23
⁵⁄₈
"
(60.0 cm)
12
¹⁄₂
"
(31.8 cm)
3
¹⁄₂
"
(8.9 cm)
5"
(12.7 cm)
13
³⁄₄
"
(34.9 cm)
12
¹⁄₁₆
"
(30.6 cm)
32" (81.3 cm)
min.
39" (99.1 cm)
max.
Recirculating chimney kit dimensions
For recirculating installations, optional Recirculating Chimney Kit
No. 4396911 (Stainless Steel) or Kit No. 4396912 (Meteorite) must
be used. These kits include a new lower chimney cover (that
replaces the lower chimney cover shipped with the island hood),
a charcoal filter and a diverter.