PRODUCT DATA SHEETS
Base Grille Water Filtration System Model WF-NL300/NL300
Capacity:
300 Gallons (1136 Liters)
Service Flow Rate:
0.5 GPM (1.89 L/min.) @ 60 psi.
Base Grille Water Filtration System Model WF-L500/L500
Capacity:
500 Gallons (1893 Liters)
Service Flow Rate:
0.5 GPM (1.89 L/min.) @ 60 psi.
It is essential that operational, maintenance, and filter
replacement requirements be carried out for the product to
perform as advertised.
Model WF-NL300
Change cartridge at least every 6-9
months. Use replacement cartridge NL 300, part# 4392857.
2000 Suggested retail price of $29.95 U.S.A./$39.95 Canada.
Model WF-L500
The filter monitor system measures the
amount of water that passes through the filter and alerts you
to replace the filter. When 90% of the filter’s rated life is used,
the filter indicator light changes from green to yellow. When
100% of the filter’s rated life is used, the filter indicator light
changes from yellow to red, and it is recommended that you
replace the filter. Use replacement cartridge L500, part#
4392857. 2000 Suggested retail price of $29.95 U.S.A./
$39.95 Canada.
The product is for cold water use only.
Do not use with water that is microbiologically unsafe or of
unknown quality without adequate disinfection before or after
the system.
Refer to the “Assistance or Service” section for the
Manufacturer’s name, address and telephone number.
Refer to the “Warranty” section for the Manufacturer’s limited
warranty.
Application Guidelines/Water Supply Parameters
*
Test requirement is 0.15 mg/L ± 10%.
**
These contaminants are not necessarily in your water supply. Performance may vary based on local water conditions.
® NSF is a registered trademark of NSF International.
Substance
Reduction
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Chlorine, Taste/Odor 2.0 mg/L N/A 0.1 mg/L N/A 95% 981788
Contaminant
Reduction
Performance
**
U.S. EPA
MCL
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
NSF Test
Number
Lead: @ pH 6.5
Lead: @ pH 8.5
0.015 mg/L
0.015 mg/L
0.16 mg/L*
0.14 mg/L*
0.007 mg/L
0.012 mg/L
0.005 mg/L
0.008 mg/L
95%
91%
97%
94%
976115
976116
Substance
Reduction
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum %
Reduction
Average %
Reduction
NSF Test
Number
Chlorine, Taste/Odor 2.0 mg/L N/A 0.1 mg/L N/A 95% 981788
Contaminant
Reduction
Performance
**
U.S. EPA
MCL
Average
Influent
Maximum
Effluent
Average
Effluent
Minimum%
Reduction
Average%
Reduction
NSF Test
Number
Lead: @ pH 6.5
Lead: @ pH 8.5
0.015 mg/L
0.015 mg/L
0.16 mg/L*
0.14 mg/L*
0.007 mg/L
0.012 mg/L
0.005 mg/L
0.008 mg/L
95%
91%
97%
94%
976115
976116
Tested and certified by NSF International against ANSI/NSF
Standard 42 for the reduction of Chlorine (Class I) Taste and Odor
and against ANSI/NSF Standard 53 for the reduction of Lead.
Tested and certified by NSF International against ANSI/NSF
Standard 42 for the reduction of Chlorine (Class I) Taste and Odor
and against ANSI/NSF Standard 53 for the reduction of Lead.
Water Supply
Water Pressure
Water Temperature
City or Well
30 - 120 psi (207 - 827 kPa)
33° - 100°F (0.6° - 37.8° C)