4. Gas orifice spuds are stamped with a number on the side.
Replace the LP gas orifice spud with the correct Natural gas
orifice spud.
Refer to the following chart for the correct Natural gas orifice
spud placement.
Natural Gas Orifice Spud Chart for Standard Surface Burners
5. Place LP gas orifice spuds in plastic parts bag for future use
and keep with literature package.
6. Replace burner cap.
7. Repeat steps 1-6 for the remaining burners, except for the
TripleTier
®
Flame burner (on some models). See “To Convert
TripleTier
®
Flame Burners” section.
To Convert TripleTier
®
Flame Burner (on some models)
1. Remove burner cap.
2. Remove the burner head using a size T20 TORX
®
screwdriver.
3. Remove the plate on the external gas orifice spud.
IMPORTANT: The TripleTier
®
Flame burner has 2 gas orifice
spuds. Do not forget to change the external gas orifice spud
located under the plate.
4. Apply masking tape to the end of a 7 mm nut driver to help
hold the internal gas orifice spud in the nut driver while
changing it. Press nut driver down onto the internal gas
orifice spud and remove by turning it counterclockwise and
lifting out. Set internal gas orifice spud aside.
5. Use a 7 mm combination wrench to remove the external
orifice spud. Turn counterclockwise remove, set external gas
orifice spud aside.
6. Replace the LP gas orifice spud with the correct Natural gas
orifice spud. Refer to the following chart for correct Natural
gas orifice spud placement.
Natural Gas Orifice Spud Chart for TripleTier
®
Flame Burners
7. Replace burner plate, head and cap.
8. Place LP gas orifice spuds in plastic parts bag for future use
and keep with literature package.
9. Reinstall the warming drawer. See the “Replace Oven Racks
and Warming Drawer” section for instructions.
10. Complete installation. See “Make Gas Connection” and
“Electronic Ignition System” sections.
Checking for proper cooktop burner flames is very important.
Natural gas flames do not have yellow tips.
IMPORTANT: You may have to adjust “LO” setting for each
cooktop burner.
A.Stamped number
Burner Location Burner Rating Size
Right front
Left front
Right rear
Left rear
6,000 Btu/h
14,000 Btu/h
12,500 Btu/h
6,000 Btu/h
1.10 mm
1.70 mm
1.61 mm
1.10 mm
A.Burner caps
B.Burner heads
C.External gas orifice spud access plate
D.Internal gas orifice spud
XXX
A
A
B
C
D
A.Plate
B.External gas orfice spud
C.Internal gas orifice spud
Burner Location Burner Rating Size
Left front (external
TripleTier
®
burner)
12,200 Btu/h 1.70 mm
Left front (internal
TripleTier
®
burner)
2,800 Btu/h 0.70 mm
A
B
C