KitchenAid LI3ZBC/W10331009C Ventilation Hood User Manual


 
13
Make Electrical Power Supply Connection to
Range Hood
1. Disconnect power.
2. Locate terminal box on top of the range hood.
3. Use UL listed wire connectors and connect black wires (B)
together.
4. Use UL listed wire connectors and connect white wires (A)
together.
NOTE: When using an In-line blower motor system, the green (or
green/yellow) ground wire in the conduit from the In-line blower
motor system is to be connected with the green (or bare) wire of
the home power supply cable and with the green/yellow wire (D)
in the terminal box.
5. Connect green (or bare) ground wire from home power supply
to the green/yellow ground wire (D) in terminal box using UL
listed wire connectors.
6. Install terminal box cover.
7. Check that all light bulbs are secure in their sockets.
8. Reconnect power.
Install Chimney Covers
1. Install damper on top of the exhaust opening. Check that the
damper opens freely.
2. Connect the vent system and seal all connections with
clamps.
Install Upper Chimney Cover
1. Slightly spread the sides of the cover apart and hook them
behind the chimney mounting brackets.
2. Attach the cover to the brackets with 2 flat head screws.
3. Securely tighten screws.
Install Lower Chimney Cover
1. Slightly spread the sides of the cover apart and hook them
behind the upper chimney.
A.Knockout in back of terminal box
B.Top of terminal box
A.White wires
B.Black wires
C.UL listed wire
connectors
D.Green, bare or yellow/green wires
E.Home power supply
F. UL listed or CSA approved
¹⁄₂
" (1.3 cm)
strain relief
WARNING
Electrical Shock Hazard
Disconnect power before servicing.
Replace all parts and panels before operating.
Failure to do so can result in death or electrical shock.
A
B
A
B
C
D
E
F
A.2 flat head screws
WARNING
Electrical Shock Hazard
Electrically ground blower.
Connect ground wire to green and yellow ground wire
in terminal box.
Failure to do so can result in death or electrical shock.
A
A