KitchenAid LI3ZGC/W10320581E Ventilation Hood User Manual


 
10
4. Use saber or keyhole saw to cut the circular vent opening.
Install Vent System
1. Install vent through the vent opening in upper cabinet or wall.
Complete venting system according to the selected venting
method. See “Venting Requirements” section.
2. Use caulking to seal exterior wall or roof opening around the
cap.
Install Range Hood
1. Remove the grease filters. See the “Range Hood Care”
section.
2. Remove mounting screws and lateral supports.
For vented installations:
Depending on your installation, remove either top or rear
rectangular vent knockout.
NOTE: Do not remove rectangular knockouts if
installation of range hood is to be non-venting
(recirculating).
Make sure damper pivot is nearest to top/back edge of
range hood.
Remove tape from damper flap.
NOTE: The exhaust adapter/damper can be installed up
to 1" (2.5 cm) on either side of the hood center to
accommodate off-center ductwork.
If using rectangular vent, attach rectangular damper/vent
connectors to the range hood using sheet metal screws.
If using round vent, attach vent transition piece
(purchased separately) to range hood top using sheet
metal screws.
NOTE: If the wall cap is directly behind the vent
connector, the dampers in the connector and wall cap
must not interfere with each other. Remove the vent
connector damper if they interfere.
3. Lift the range hood up under cabinet and determine final
location by centering beneath cabinet. Mark on the underside
of cabinet the location of the 4 keyhole mounting slots on the
range hood. Set range hood aside on a covered surface.
4. Use ¹⁄₈" (3 mm) drill bit and drill 4 pilot holes as shown.
5. Install the 4 - 4.5 x 13 mm mounting screws in pilot holes.
Leave about ¹⁄₄" (6.4 mm) space between screw heads and
cabinet to slide range hood into place.
A. Lateral supports
B. Mounting screws
Circular vent opening
Cabinet
cutouts
*From wall, not
cabinet frame
*5"
(12.7 cm)
B
A
A
A. Vertical vent
B. Sheet metal screws
C. Hinge pin
D. Vent knockouts
E. Horizontal vent
A. Keyhole slot
A. Drill pilot hole
C
E
B
A
B
D
A
A
¹⁄₄"
(6.4 mm)