KitchenAid W10246119C Range User Manual


 
12
2. Use ³⁄₈" nut driver to connect the neutral (white) wire to the
center terminal block post with one of the 10–32 hex nuts.
3. Connect line 2 (red) and line 1 (black) wires to the outer
terminal block posts with 10-32 hex nuts.
4. Securely tighten hex nuts.
NOTE: For power supply cord replacement, use only a power
cord rated at 250 volts minimum, 40 amps or 50 amps that is
marked for use with nominal 1³⁄₈" (3.5 cm) diameter
connection opening, with ring terminals and marked for use
with ranges.
5. Tighten strain relief screws.
6. Replace terminal block access cover.
Direct Wire Installation: Copper or Aluminum Wire
This range may be connected directly to the fuse disconnect or
circuit breaker box. Depending on your electrical supply, make
the required 3-wire or 4-wire connection.
1. Strip outer covering back 3" (7.6 cm) to expose wires. Strip
the insulation back ³⁄₈" (1.0 cm) from the end of each wire.
2. Allow enough slack in the wire to easily attach the wiring
terminal block.
3. Complete electrical connection according to your type of
electrical supply (4-wire or 3-wire connection).
4-wire Connection: Direct Wire
Use this method for:
New branch-circuit installations (1996 NEC)
Mobile homes
Recreational vehicles
In an area where local codes prohibit grounding through the
neutral
1. Cut out and remove part of the metal ground strap (B).
2. Use a Phillips screwdriver to remove the ground-link screw
from the back of the range. Save the ground-link screw and
the end of the ground link under the screw.
3. Pull the wires through the strain relief on bottom of range.
Allow enough slack to easily attach wiring to the terminal
block.
4. Attach terminal lugs to line 1 (black), neutral (white), and line 2
(red) wires. Loosen (do not remove) the setscrew on the front
of the terminal lug and insert exposed wire end through
bottom of terminal lugs. Securely tighten setscrew to torque
as shown in the following Bare Wire Torque Specifications
chart.
A.10–32 hex nut
B.Line 2 (red)
C.Ground-link screw
D.Neutral (white) wire
E.Line 1 (black)
A
B
C
D
E
3"
(7.6 cm)
³⁄₈"
(1.0 cm)
A.Metal ground strap
B.Discard
C.Ground-link screw
A.Terminal block
B.Ground-link screw
C.Cord/conduit plate
D.Bare (green) ground wire
E.Line 2 (red) wire
F. Neutral (white) wire
G.Line 1 (black) wire
A.Terminal lug
B.Setscrew
C.Line 2 (red) wire
D.Neutral (white) wire
E.Line 1 (black) wire
A
B
C
A
B
C
D
E
G
F
A
B
C
DE