Kobe Range Hoods CH8136SQ Ventilation Hood User Manual


 
6
Figure 5
Ductwork Installation
5. Use 6” round pipe to connect the plastic exhaust on the hood to the ductwork above. Use
duct tape to make all joints secure and air tight. Refer to Figure 6.
6. For 7” round ductwork, attach the 7” round duct adapter (provided) to the 6” round plastic
exhaust on the hood. Refer to Figure 7.
Figure 6 Figure 7
Wiring to Power Supply
S AF ET Y W A R N IN G
RISK OF ELECTRICAL SHOCK. THIS RANGE HOOD MUST BE PROPERLY GROUNDED.
MAKE SURE THIS IS DONE BY SPECIALIZED ELECTRICIAN IN ACCORDANCE WITH ALL
APPLICABLE NATIONAL AND LOCAL ELECTRICAL CODES. BEFORE CONNECTING
WIRES, SWITCH POWER OFF AT SERVICE PANEL AND LOCK SERVICE PANEL TO
PREVENT POWER FROM BEING SWITCHED ON ACCIDENTALLY.
7. Connect three wires (black, white and green) to house wires and cap with wire
connectors.
8. Connect according to color: black to black, white to white, and green to green.
9. Test the operation of the hood before moving on to the next step. Make sure power is
supplied to the hood.
Duct Cover Installation
NOTE: BE CAREFUL WHEN USING ELECTRICAL SCREWDRIVER, DAMAGE TO THE
HOOD MAY OCCUR.
Mounting
Screws
7” Round
Adapter
6” Round
Plastic Exhaust