Kobe Range Hoods IS2042GS Ventilation Hood User Manual


 
6
SAFETY WARNING
RISK OF ELECTRICAL SHOCK. THIS
RANGE HOOD MUST BE PROPERLY
GROUNDED. MAKE SURE THIS IS DONE
BY QUALIFIED ELECTRICIAN IN
ACCORDANCE WITH ALL APPLICABLE
NATIONAL AND LOCAL ELECTRICAL
CODES. BEFORE CONNECTING WIRES,
SWITCH POWER OFF AT SERVICE PANEL
AND LOCK SERVICE PANEL TO PREVENT
POWER FROM BEING SWITCHED ON
ACCIDENTALLY.
7. Route house wiring into the ceiling as close
to the installation location as possible.
Allow additional length to drop down from
the ceiling to the electrical box.
8. Connect the electrical wires according to
color (black to black, white to white, and
green to green) and cap with wire
connectors. Green wire must be grounded
to reduce risk of electrical shock.
Ductwork Installation
9. Use 6” round aluminum or steel pipe (not
provided) to connect the 6” round damper
on the hood to the ductwork above. NOTE:
Place 6” round duct pipe over the damper.
Seal with duct tape to make all joints secure
and tight. NOTE: MAKE SURE FLAPS ON
DAMPER CAN OPEN & CLOSE FREELY.
(Figure 6)
Figure 4
Figure 5
Figure 6
Wiring to Power Supply