INSPECTION AND ADJUSTMENTS
IMPORTANT! Read before operating mixer.
It is the responsibility of the owner to make sure the mixer is set up properly.
The following recommendations should be helpful.
ELECTRONIC SCALES
Scale Indicator: Refer to the electronic scale operator’s manual for adjustment information. The operator’s manual
for the Electronic Scales should be kept with this manual. Additional copies of scale manuals may be obtained
through Kuhn Knight, Inc.
Load cells and weigh bars should be kept clean, dry and lubricated to ensure dependability.
NORMAL SCALE ACTIVITY
Some warm up scale drift may occur after the scale is turned on but should zero balance within 10 to 15 minutes.
Scale may zero shift over night due to temperature changes.
3150 TO 3195 AND
3136 BEFORE S/N B0001,
3142
BEFORE S/N B0001
Vertical check bolts must not be tight and should be free to
rotate by hand. There should be 1/16” to 3/32” free play when
properly adjusted on level ground.
3150 - 3195 AND
3136 BEFORE S/N B0001,
3142
BEFORE S/N B0001
Check arm assembly must be free to rotate slightly
by hand when mixer is on level ground with mounting
bolts tight.
3136 BEFORE S/N B0001,
3142
BEFORE S/N B0001
PIN CHECK BEARING should be centered on the pin
when mixer is on level ground. Adjustment can be made
by loosening the mounting bolts, centering pin check
assembly on the pin and tightening the mounting bolts. If
bushing cannot be centered load cells may require
adjustment.