Lennox Hearth T300P Range User Manual


 
INSTALLATION
Page 9
THERMOSTAT INSTALLATION:
NOTE: Always Disconnect Power Before Perform-
ing The Thermostat Installation.
A 24-volt wall thermostat and 20 feet of 18-gage ther-
mostat wire is included in your stoves accessory pack-
age. It is recommended that the thermostat and ther-
mostat wire be installed by an authorized Lennox
Hearth Products dealer.
Installation Steps:
1. Unplug stove power cord from the wall outlet.
2. Locate the thermostat terminal block (see illustra-
tion).
3. Loosen the two terminal screws on the terminal
block and remove the jumper.
4. Connect the two wires from your thermostat to the
terminals (one per terminal). Ensure that the purple
wires from the harness remain connected to the ter-
minal block and tighten the terminal screws. Make
sure the wires are firmly connected to the thermo-
stat.
5. Plug in the stove and you are ready to operate with
your thermostat!
IMPORTANT: IF THE WALL THERMOSTAT PRO-
VIDED IS NOT USED, THE JUMPER IS REQUIRED
FOR THE STOVE TO OPERATE.
Terminal Block for Thermostat
Leave Jumper on, If Thermostat Is Not
Used
Remove Jumper if Thermostat Is
To Be Used
Model T300P Series
(viewed from stove back)
Jumper