ENGLISH
27
ELECTRICAL CONNECTIONS (cont.)
Observe all governing codes and local
ordinances.
ᕡ Disconnect the power supply.
ᕢ At the circuit breaker box, fuse box or junction
box, connect appliance and power supply cable
wires as shown.
WARNING
If connecting to a 4-wire power supply cable
electrical system, the appliance frame
connected ground wire MUST NOT be
connected to the neutral wire of the 4-wire
electrical system.
IF COOKTOP IS USED IN A NEW BRANCH CIRCUIT INSTALLATION (1996 NEC), MOBILE
HOME, RECREATIONAL VEHICLE, OR WHERE LOCAL CODES DO NOT PERMIT GROUNDING
TO THE NEUTRAL (WHITE) WIRE
4-WIRE GROUNDED JUNCTION BOX
Cable from power supply
Black
wires
White wire
(no connection)
Red
wires
Junction box
UL-listed conduit
connector
Cable from cooktop
Green wire (ground)
Ground
Wire
COOKTOP INSTALLATION
ᕡ Visually inspect the cooktop for damage.
Make sure all cooktop screws are tight
(see below for locations).
ᕢ Carefully lower the cooktop into the counter- top
cutout, making sure not to trap any wires.
NOTE: Do not use caulking compound. The
cooktop must be removable, should service be
required.
Screws