LG Electronics LDE3015ST Double Oven User Manual


 
10
ELECTRICAL CONNECTIONS
4-WIRE CONNECTION: CONDUIT
1. Follow the instructions under “Install the conduit as
follows” on page 9 to correctly install the strain relief.
DO NOT install the conduit without a strain relief.
2. Loosen the 2 lower left and right screws from the
terminal block. (Refer to Figure 12.)
Remove the lower 2 center screws.
3. Remove ground strap and discard as shown in
Figure 12.
Do not discard any screws.
4. Attach the ground bare wire end to range frame and
secure it in place with the ground screw (Refer to
figure 12.)
5. Insert the bare wire (white/neutral) end through the
center terminal block opening.
6. Insert the two side bare wire ends into the left and the
right terminal block opening.
Tighten the 3 screws securely into the terminal block.
(approximately 35 - 50 IN-LB)
7. Go to page 11.
4-wire connection
Remove
ground
strap and
discard
Terminal
block
Wire
ends
Conduit
connection plate
Black White Red
Ground
strap
Ground
Wire
Ground
Screw
FIGURE 12