LG Electronics LDE3017SB Double Oven User Manual


 
9
ENGLISH
Part 3 ELECTRICAL CONNECTIONS
4-wire connection: conduit
1. Follow the instructions under “Install the conduit as
follows” on page 7 to correctly install the strain
relief.
DO NOT install the conduit without a strain relief.
2. Loosen the 2 lower left and right screws from the
terminal block. (Refer to Figure 12.)
Remove the lower 2 center screws.
3. Remove ground strap and discard as shown
in Figure 12.
Do not discard any screws.
4. Attach the ground bare wire end to range frame
and secure it in place with the ground screw (Refer
to figure 12.)
5. Insert the bare wire (white/neutral) end through the
center terminal block opening.
6. Insert the two side bare wire ends into the left and
the right terminal block opening.
Tighten the 3 screws securely into the terminal
block. (approximately 35 - 50 IN-LB)
7. Go to page 10.
FIGURE 12
4-wire connection