7
ENGLISH
Part 3 ELECTRICAL CONNECTIONS
FIGURE 7
FIGURE 8
3-wire connection
Assemble the strain relief
to the 1
3
/
8
” opening in
Conduit connection plate
Separate Strain Relief
before installation
3-wire connection with a power supply cord
WARNING
• The middle (neutral or ground) wire of a 3
wire power cord or a 3 wire conduit has to
be connected to the middle post of the
main terminal block. The remaining two
wires of the power cord or conduit have to
be connected to the outside posts of the
main terminal connection block.
- Failure to do so can result in electrical shock, severe
personal injury or death.
Gloves
Safety Glasses
Tape Measure
Pencil
Rear filler & 2 Screws
(LSE Series only)
Install the power cord as follows:
For power cord installations, Hook the strain relief
over the power cord hole (1
3
/
8
”) located below the rear
of lower oven. Insert the power cord through the
strain relief and tighten it. (Refer to Figure 7.)
DO NOT install the power cord without a strain relief.
1. Remove the lower 3 screws from the terminal block
and retain them. (Refer to Figure 8.)
2. Insert the 3 screws through each power cord
terminal ring and into the lower terminals of the
terminal block.
Make sure that the center wire (white/neutral) is
connected to the center lower position of the
terminal block.
3. Tighten 3 screws securely into the terminal block.
Do not remove the ground strap connections.
4. Go to page 10.