LG Electronics LDG3015ST Oven User Manual


 
8
INSTALLATION INST RUCTIONS
Your range is designed to operate at a pressure of
5” of water column on natural gas or 10” of water
column on LP.
Make sure you are supplying your range with the type
of gas for which it is configured.
This range is convertible for use on natural or LP gas.
When using this range on LP gas, conversion must be
made by a qualified LP installer before attempting to
operate the range.
For proper operation, the pressure of natural gas
supplied to the regulator must be between 5” and 13”
of water column.
For LP gas, the pressure supplied to the regulator
must be between 10” and 13” of water column.
When checking for correct operation of the regulator,
the inlet pressure must be at least 1” more than the
operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the
range must remain in the supply line regardless of
which type of gas is being used.
A flexible metal appliance connector used to connect
the range to the gas supply line should have an I.D. of
5/8” and a max of 5ft. In Canada, flexible connectors
must be single wall metal connectors less than 6 feet
in length.
GAS PIPE AND ELECTRICAL OUTLET LOCATIONS
1. PROVIDE ADEQUATE GAS SUPPLY
14
5
/
16
2”
3”
Recommended area for 120V
outlet on rear wall and area for
through-the wall connection of
pipe stub and shut-off valve.
Recommended area for
through-the floor connection
of pipe stub and shut-off valve.
30”
9
1
/
16
8
19
/
32
2
3
/
8
11
3
/
32