LG Electronics LRE30453S Range User Manual


 
7
Part 3 ELECTRICAL CONNECTIONS
Follow the instructions under “
CONNECT RANGE
CORD
” on page 5 to correctly install the strain relief.
1. Remove the lower 3 screws from the terminal block
and retain them. (Refer to Figure 9.)
Remove the ground screw and retain it.
2. Remove ground strap and discard as shown
in Figure 9.
Do not discard any screws.
3. Insert the ground screw into the power cord ground
wire terminal ring and secure it to the range frame.
4. Insert the 3 screws through each power cord
terminal ring and into the lower terminals of the
terminal block. Make sure that the center wire
(white/neutral) is connected to the center lower
position of the terminal block.
Tighten 3 screws securely into the terminal block.
5. Go to page 9.
Install the conduit as follows:
Remove the Conduit connection plate from the rear of
drawer body and rotate it as shown in Figure 5. The
conduit hole (1
1
/
8
”) must be used.
First, prepare conduit wires as shown in Figure 10.
Second, install conduit as shown in Figure 6.
For conduit installations, after purchasing a strain
relief, insert it in the conduit hole (1
1
/
8
”). Then install
the conduit through the body of strain relief and
fasten the strain relief with its ring. Reinstall the
bracket.
For conduit connections :
If the wire in the conduit is copper it must be 8 or 10
AWG wiring.
If the wire in the conduit is aluminum it must be 6 or 8
AWG wiring.
1. Loosen the lower 3 screws from the terminal block.
(Refer to Figure 11.)
2. Insert the bare wire (white/neutral) end through the
center terminal block opening.
Do not remove ground strap connections.
3. Insert the two side bare wire ends into the lower left
and the lower right terminal block opening.
Tighten the 3 screws securely into the terminal block.
(approximately 35 - 50 IN-LB)
4. Go to page 9.
FIGURE 10
3-wire connection: conduit
or
3 wire 4 wire
FIGURE 9
4-wire connection
4-wire connection with a power supply cord
WARNING
• Only a 4-conductor power-supply cord kit
rated 120/240 volts, 50 amperes and
marked for use with ranges with closed-
loop connectors or open-end spade lugs
with upturned ends shall be used. The
middle (neutral) wire of the power cord or
4-wire conduit has to be connected to the
middle post of the main terminal block. The
other two wires of the power cord or
conduit have to be connected to the
outside posts of the main terminal
connection block. The 4th ground wire
must be connected to the frame of the
range with the ground screw.
- Failure to do so can result in electrical shock, severe
personal injury or death.
4
FIGURE 11
3-wire connection
ENGLISH