Liebherr 48 Refrigerator User Manual


 
Freestanding/Semi Built In Models
CS 1311, 1360 - SBS 26S1
Cabinet Opening Dimensions
3"
(76 mm)
The appliance can be integrated into the kitchen units.
To adapt the appliance to the height of the row of kitchen units,
a suitable top cupboard can be fitted above the appliance.
Unit Venting
DO NOT restrict the air flow. An air flow of at least 2" (50mm)
must be provided. The opening can either be directly over the
appliance or on the back of the cabinet on top of the unit (see
ventilation requirements).
The CS models can be installed in standard 24" (609mm) deep
cabinets. You will only have to make sure that the door swing
clearance is enough. It is possible to push all CS models to the
rear wall of the cabinet without modification.
When installing the appliance next to a wall, a distance on the
hinge side of 1 13/32 inches (36 mm) minimum is required be-
tween the appliance and the wall to allow for the door handle
projection when the door is open.
Minimum Cabinet Opening Dimensions:
CS 1311, 1360
A. 23-7/8" (606 mm)
B. 24" (609 mm)
C. 85-29-32" (2182 mm)
D. 79-13/32" (2017 mm)*
SBS 26S1 (CS 1311 & CS 1360)
A. 47-23/32" (1212 mm)
B. 24" (609 mm)
C. 85-29/32" (2182 mm)
D. 79-13/32" (2017 mm)*
3
*Note: The given cabinet opening height dimension includes 2" for top air vent. If you choose to place the
vent above the cabinet or in a soffit, you will need to adjust the height dimension accordingly.