Connection to the Water Supply
1. Install the shut-off valve, water filter and auto-
matic shut-off device as required.
Note
The solenoid valve is located at the rear of
your unit.
2. The 1/4" OD copper
tubing between the
shut-off valve and
solenoid valve has a
Metric R3/4 male con
-
nector (Figure 15).
Make sure there is
approximately 30" (70
cm) of excess tubing
behind the unit for
easy connection.
Note
A R3/4(metric) to a
1/4" OD adapter is
supplied with the ice
-
maker.
3. Open the shut-off
valve for the water
supply and check the
entire water system for leaks. Before the appli
-
ance is used for the first time a licensed plumb-
er should bleed air from the system.
4. Insert the electrical plug for the combined refrig
-
erator/freezer into the electrical outlet (Figure
16)
.
5. Move the combined refrigerator-freezer into final
position in the room.
Figure 16
ICEMAKER
Water Connection
Please read the first three points of the safety
instructions and warnings before connecting the
appliance to the main water supply.
The water pressure must be between 21.8-87.0
psi (1.5-6 bar).
Use a 1/4" OD copper line to connect the water
supply to the solenoid valve. This is not sup
-
plied with the refrigerator (Figure 14).
A shut-off valve, such as the saddle valve illus-
tration here, must be installed between the hose
line and the main water supply so the water sup
-
ply can be stopped if necessary.
Do not install the shut-off valve behind the
refrigeration unit.
IM002
Figure 14
If you have hard water, we recommend you install
a water softener. Also, a filter must be installed if
the water contains solids such as sand.
All equipment and devices used to supply the
water to the appliance must comply with the cur
-
rent regulations for your geographical area.
Figure 15