Lincoln 1400 Convection Oven User Manual


 
Impinger I -–1000 Series Service Manual - Domestic
49
REVERSING CONVEYOR DIRECTION
SN 100-4389 (BODINE)
1. Shut off power at main breaker.
2. Remove control panel top.
3. Turn reversing switch (located on relay box) to obtain desired belt direction.
4. Reassemble in reverse order.
SN 4390-14974 1000 SERIES GAS OVEN
SN 4390-14791 1200 SERIES
All ovens leaving our plant are wired to operate conveyors from left to right. To reverse conveyor
direction, use the following procedure.
1. Shut off power at main breaker.
2. Remove control panel top.
3. Remove cover from relay box.
4. Reverse wires fastened to terminals A+ and A-.
5. Reverse wires fastened to terminals T1 and T2. Both set of leads must be reversed or oven
will run at maximum speed with no speed adjustment possible.
STEPPER DRIVE SYSTEM
SN 14975 AND ABOVE 1000 SERIES GAS OVEN
SN 14792 AND ABOVE 1200 SERIES
1. Shut off power at main breaker.
2. Remove control panel top.
3. Remove relay box cover.
4. Change position of dip switch #1 on stepper control board.
5. Reassemble in reverse order.
MINI CIRCUIT BREAKER
1. Shut off power at main breaker.
2. Remove control panel top and front panel.
3. Disconnect two (2) wires from circuit breaker.
4. Remove knurled mounting nut and remove.
5. Reassemble in reverse order.
NOTE: Be sure to reset breaker before operating.
BEARING, CONVEYOR
SN 100-2163
1. Remove conveyor from oven and place of flat surface.
2. Remove connecting links from conveyor belting. See Installation and Operting Instructions Manual.
3. Remove conveyor belting from conveyor.
DRIVE END
4. Remove drive sprocket from drive shaft.
5. Remove drive shaft from end of conveyor frame.
6. Remove bearing retaining clips from ends of drive shaft.
7. Slide bearing off drive shaft.
8. Reassemble in reverse order.
IDLER END
4. Remove idler shaft from end of conveyor frame.
5. Slide bearing off idler shaft.
6. Reassemble in reverse order.