Lincoln 1400 Oven Accessories User Manual


 
Impinger I -–1000 Series Service Manual - Domestic 45
Turn speed control dial clockwise to its maximum speed position.
PLACE DIGITAL VOLTMETER LEADS ON terminal S1 and S2, adjust the max pot. for a
reading of 3.4 VDC.
Place METER LEADS on terminals A1 and A2. Adjust the reg. pot. for a reading of 125 VDC.
NOTE: In some instances when the input AC voltage runs on the high side of the normal
input range, you may have difficulty adjusting the max. pot. for a reading of 3.4 VDC. In this
instance, a reading of 3.45 VDC is acceptable.
Adjust speed pot to obtain the proper time setting for the conveyor to meet customers desired
speed .
Check conveyor travel in a no load situation to insure conveyor belt is traveling at a constant
speed.
GND
S 3
S 2
S 1
A 2
A 1
F 2
F 1
L 2
L 1
3 A.
FUSE
D. C. CONTROL BOARD "BODINE" S/N 100-4389
REG MIN MAX
D. C. CONTROL BOARD "BODINE" S/N 100 4389
( TOP VIEW )
3 A. FUSE
TERMINAL