Lincoln 1454-000-N Oven User Manual


 
Global Global
Gas Supply Pressure Recommendations:
Gas Type Supply (Inlet) Pressure (mbar)
Recommended
Minimum
Gas Pipe Size
Natural 9-14” WC (2.2 kPA / 22.4 mbar - 3.5 kPa / 34.9 mbar) 2” (51 mm)
LP 11-14” WC (2.7 kPa / 27.36 mbar - 3.5 kPa / 34.9 mbar) 2” (51 mm)
*Gas supply pressures are dependent on local gas type and on all applicable local codes. Agency approved exible
connection to each oven must be minimum ¾” (19 mm) NPT and length must not exceed six (6) feet (1829 mm).
Electrical Service:
Each oven deck requires voltage, phase and hertz as indicated by model number. Neutral must be grounded
at electrical service and receptacle properly polarized. Gas 120V units have a cord with NEMA 5-15 plug.
All other models have terminal block connections. It is recommended that a separate circuit breaker be
provided for each oven deck.
Recommended Minimum Clearances:
Rear of oven to combustible surface: 6” (152 mm). Clearance on right side from other cooking equipment: 24”
(610 mm). Clearance required to remove conveyor for cleaning: 11’ (3553 mm).
Warranty:
All new impinger
®
ovens installed in the United States and Canada come with a one (1) year parts and labor
warranty starting from the date of start-up/check-out. All ovens installed in locations other than in the US
and Canada are warranted for one (1) year parts and ninety (90) days labor starting from the date of start-up/
check-out. Start-up/check-out must occur within 24 months of date of manufacture.
General Information:
All 1600 Models
Length Depth
Height
Single
Height
Double Stacked
78”
(1981 mm)
58”
(1473 mm)
52”
(1321 mm)
64 ⁵/₈”
(1641 mm)
Model
Number
Agency Utility Input Rate Voltage Hertz Phase Supply
1433-000-E NSF/CE Natural
120,000 BTU/Hr.
32.5 kW
126.6 MJ
230 50 1 3
1450-000-U NSF/CSA Natural 120 60 1 3
1456-V00-B AGA/NSF Natural 240 50 1 3
1434-000-E NSF/CE LP 230 50 1 3
1447-000-N -- LP 220 60 1 3
1451-000-U NSF/CSA LP 120 60 1 3
1457-V00-B AGA/NSF LP 240 50 1 3
1421-000-E NSF/CE Electric
27 kW
400/230 50 3 5
1452-000-U NSF/UL/CSA Electric 120/208 60 3 5
1453-000-U NSF/UL/CSA Electric 120/240 60 3 5
1454-000-N NSF/UL/CE Electric 380Y/220 50 3 5
1455-000-N NSF/UL/CE Electric 415Y/240 50 3 5
1458-000-E NSF/UL/CE Electric 400 50 3 4
NOTE: Panel setups are added as kit numbers to the end of the model number to complete the oven order; (example: 1450-000-U-K1801 is a 1450-000-U with
standard setup, left to right.)
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN
Technical Drawings:
NOTE: Specications subject to change without notication.
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN
1400 Series | Impinger® I Single Belt Conveyorized Oven
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN
58”
(1473 mm)
81”
(2057 mm)
28”
(711 mm)
20”
(508 mm)
40 3/16”
(1021 mm)
DOOR SWING
GAS SUPPLY
3/4” (19 mm) NPT
33 3/4”
(857 mm)
46 1/2”
(1181 mm)
13”
(330 mm)
3/4” (19 mm)
NPT | Gas
48 5/8”
(1235 mm)
21 5/8”
(549 mm)
7 1/2”
(191 mm)
20”
(498 mm)
Shown with Open
Glass Access Door
64 5/8”
(1641 mm)
3 1/4”
(83 mm)
DOOR OPEN
3 1/4”
(83 mm)
DOOR OPEN