InstaSlice Operator Manual
4
CLEANING INSTRUCTIONS (CONT’D)
3. DO NOT WIPE BLADES OR USE SCRUB PADS IN THIS MACHINE. WIPING ACROSS THE SHARP
EDGE OF BLADES CAN CAUSE INJURY AND WILL DULL THE BLADES.
4. Do not put this machine in a dishwasher or dish machine with soaps, detergents, or other alkaline
chemicals that can harm the machine.
5. After cleaning, let the machine air dry.
6. Lubricate sliding parts with mineral oil or Petro Gel after each use. Never use cooking oil as it will cause
the machine to become sticky!
BLADE / PUSHER HEAD MAINTENANCE
1. Examine the pusher head fingers. If they are nicked or burred smooth the rough edges with a small flat file.
The spaces between the fingers must be uniform. Straighten any bent fingers.
2. Check the clearance between the pusher head fingers and the blades. Make sure they do not rest on or
touch the blades at any point when you move the head through its full travel. If there is contact,
adjustments must be made. PUSHER HEAD FINGERS MUST NEVER CONTACT BLADES.
Adjust Pusher Head Finger spacing by placing a screwdriver between Pusher Head Fingers and gently
rotate up/down. You may also adjust the entire Pusher Head Assembly by loosening the set screws
underneath a rotating the guide rod as needed – tighten set screws.
REPLACING BLADE ASSEMBLY
1. Individual blades cannot be replaced. Replacement blades are available in assemblies only.
2. Loosen the two thumbscrews on the top of the machine.
3. Push the top of the blade assembly from the back towards the front and lift out. Replace in the opposite
manner and tighten the two thumbscrews.
4. Dispose of used blade assemblies properly.
CAUTION:
KEEP THE SHARP BLADE EDGES AWAY FROM HANDS WHEN HANDLING THE
MACHINE.
!