Magic Chef 12842123 Refrigerator User Manual


 
20
Water Filter
System Specification and Performance Data Sheet
Refrigerator Water Filter Cartridge Model UKF8001AXX
Specifications
Service Flow Rate (Maximum).............................................0.78 GPM (2.9 L/min)
Rated Service Life UKF8001AXX-750 (Maximum)......750 gallons/2838 liters
Maximum Operating Temperature .....................................100° F / 38° C
Minimum Pressure Requirement........................................35 psi/241 kPA
Minimum Operating Temperature......................................33° F/1° C
Maximum Operating Pressure.............................................100 psi /689 kPA
Performance Data
1000 Apollo Road
Eagan, Minnesota 55121-2240
651.450.4913
EPA EST #35917-MN-1
100834/B
The PuriClean
®
II retractable water filtration system uses a
UKF8001AXX replacement cartridge. Timely replacement of
filter cartridge is essential for performance satisfaction from
this filtration system. Please refer to the applicable section of
your Use & Care Guide for general operation, maintenance
requirements and troubleshooting. Suggested retail price of
replacement water filter is $39.99.
This system has been tested according to ANSI/NSF 42 and
53 for reduction of the substance listed above. The
concentration of the indicated substances in water entering
the system was reduced to a concentration less than or equal
to the permissible limit for water leaving the system, as
specified in ANSI/NSF 42 and 53.
* Tested using a flow rate of 0.78 gpm; pressure of 60 psig; pH of 7.5 + 0.5; temp. of
68° + 5° F (20° + 3° C)
** Measurement in Particles/ml. Particles used were 0.5 - 1 microns
*** NTU - Nephelometric Turbidity Units
General Use Conditions
Read this Performance Data Sheet and compare the
capabilities of this unit with your actual water treatment
needs.
DO NOT use this product where water is
microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
System certified for cyst reduction may be used on
disinfected water that may contain filterable cysts.
USE ONLY WITH COLD WATER SUPPLY. CHECK FOR
COMPLIANCE WITH THE STATE AND LOCAL LAWS
AND REGULATIONS.
TM
Standard No. 42: Aesthetic Effects
Taste and Odor Reduction
Chlorine Taste & Odor
Mechanical Filtration Unit
Particulate Reduction Class 1
Standard No. 53: Health Effects
Chemical Reduction Unit
Lead, Atrazine, Lindane, Benzene,
Carbofuran, p-Dichlorobenzene, Mercury
& Toxaphene Reduction
Mechanical Filtration Unit
Cyst, Turbidity and Asbestos Reduction
Tested and certified by NSF International against ANSI/NSF Standards 42 & 53
in models UKF8001AXX-750 for the reduction of:
Parameter
Chlorine
T&O
Particulate**
USEPA
MCL
Standard No. 42: Aesthetic Effects
Influent
Challenge Concentration
2.0 mg/L ± 10%
at least 10,000 particles/ml
Influent
Average
1.88 mg/L
5,700,000 #/ml
Average
<0.05136364 mg/L
30,583 #/ml
Maximum
0.06 mg/L
69,000 #/ml
Average
>97.26%
99.52%
Minimum
96.84%
98.94%
Min. Required
Reduction
50%
85%
Effluent % Reduction
Parameter
Turbidity
Cysts
Asbestos
Lead at pH 6.5
Lead at pH 8.5
Mercury at pH 6.5
Mercury at pH 8.5
Atrazine
Benzene
Carbofuran
p-Dichlorobenzene
Lindane
Toxaphene
USEPA
MCL
1 NTU**
99.5% Reduction
99% Reduction
0.015 mg/L
0.015 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
Standard No. 53: Health Effects
Influent
Challenge Concentration
11 ± 1 NTU***
Minimum 50,000/L
10
7
10
8
fibers/L; fibers >10 micrometers in length
0.15 mg/L + 10%
0.15 mg/L + 10%
.006 mg/L ± 10%
.006 mg/L ± 10%
0.009 mg/L + 10%
0.015 mg/L ± 10%
0.08 mg/L ± 10%
.225 mg/L ± 10%
0.002 mg/L + 10%
0.015 ± 10%
Influent
Average
10.7 NTU
166,500 #/L
155 MF/L
0.153 mg/L
0.150 mg/L
0.006 mg/L
0.006 mg/L
0.009 mg/L
0.014 mg/L
0.081 mg/L
0.208 mg/L
0.002 mg/L
0.015 mg/L
Average
0.31 NTU
<1 #/L
<1 MF/L
<.001 mg/L
<.001 mg/L
0.0003 mg/L
0.0008 mg/L
<0.002 mg/L
0.0006 mg/L
<0.001 mg/L
<0.0005 mg/L
0.000 mg/L
<0.001 mg/L
Maximum
.049 NTU
<1 #/L
<1 MF/L
<.001 mg/L
<.001 mg/L
0.0005 mg/L
0.0015 mg/L
0.002 mg/L
0.0011 mg/L
<0.001 mg/L
<0.0005 mg/L
<0.0001 mg/L
<0.001 mg/L
Average
97.09%
>99.99%
>99.99%
>99.35%
>99.33%
95.70%
86.22%
76.99%
95.71%
98.74%
99.76%
98.72%
92.97%
Minimum
95.20%
>99.99%
>99.99%
>99.29%
>99.29%
90.91%
75.93%
75.31%
92.14%
98.46%
99.74%
96.50%
91.67%
Min. Required
Reduction
0.5 NTU
>99.95%
99%
0.10 mg/L
0.10 mg/L
0.002 mg/L
0.002 mg/L
0.003 mg/L
0.005 mg/L
0.04 mg/L
0.075 mg/L
0.0002 mg/L
0.003 mg/L
Effluent % Reduction