OPERATING YOUR APPLIANCE
Temperature Control and Display
1. The temperatures in upper zone and lower zone can be independently controlled and displayed.
2. The temperature in either zone can be controlled between 39°F to 61°F (4℃ to 16℃). (The zone
temperature may have a tolerance of +/-5°F (+/-3℃) from setting depending on different loading
and ambient conditions.)
3. The temperature display, indicator
, control pads (warmer) and (colder) near the symbol
(left side) are for upper zone of the wine cooler.
4. The temperature display, indicator
, control pads (warmer) and (colder) near the symbol
(right side) are for lower zone of the wine cooler.
5. The indicators
and , and the control pads (lock) and (light) are for both zones.
Indicators Lights
• When lit, the
indicator light indicates that the unit is in the “Stand by” mode.
• When lit, the
indicator light indicates that all of the control pads are locked and no
adjustment can be made to the unit.
• When lit, the
indicates that the corresponding zone is in the refrigeration cycle (compressor
is running). The indicator will go off once the desired temperature is reached. Note: The
light will remain on and the compressor may continue to run for several minutes after
the desired temperature is reached.
Standby
1. When the unit is plugged in all of the display indicators will light for 3 seconds and an audible
beep will be heard. The unit will automatically resume the previous settings from when the unit
was unplugged. If the unit was previously in the “Stand By” mode when unplugged it will resume
in the “Stand By” mode and the
indicator will be lit.
2. You can manually set the unit to the “Stand By” mode by pressing and holding both the
and
pads simultaneously of the lower zone located on the right side of the control panel for
approximately 3 seconds. The control pad must be “unlocked” to set the unit to the “Stand By”
mode. The
indicator light will illuminate to confirm this setting.
Lock and Unlock
The lock feature is designed to prevent the settings of your wine cooler from being adjusted
accidentally. In order to adjust any of the settings you must unlock the control panel by pressing the
“lock” pad for approximately 3 seconds. Once the unit is unlocked an audible beep will be heard and
the “lock” indicator light will go out.
If no selection is made to adjust the unit in approximately one minute the control panel will
automatically return to the “lock” mode.
To lock the unit manually press the “lock” pad.
EN
6