Makita VC4710 Food Saver User Manual


 
22
Makita VC4710
Original Instruction
B
6.2.6 Replacing filter element
(Auto-Filter Cleaning
System)
Never use the vacuum without a
filter.
For safety and extended life of main
filter elements we strongly recom-
mend using filter bag when unit is
operated with certified HEPA fil-
ters.
1. Be sure that the vacuum is
switched off and unplugged.
2. Open the retaining clamps
(A) and remove the upper
section of the vacuum clean-
er.
Removing the filter elements:
3. Open fi lter tension part (B).
4. Remove carefully the cas-
settes with fi lter elements.
Inserting the filter elements:
5. Insert new fi lter elements (C)
into the cassettes (D).
6. Attach the cassettes with the
fi lter elements onto the upper
section of the vacuum.
7. Fix the fi lter tension part (B).
8. Dispose of the used fi lter
elements in accordance with
applicable regulations.
9. Attach the upper section of
the vacuum cleaner.
10. Close the retaining clamps
(A). Ensure that the retaining
clamps fit properly.
B
A
A
C
D
B
A
A